SANYO DENKI SANMOTION
LINEAR SERVO MOTOR
Linear Servo Motor
High Acceleration Motion
With a smaller and lighter linear motor coil compared to our conventional product,* this motor features an increased maxi mum thrust and a 7% higher maximum acceleration. Also, the thrust at high speeds has been increased for fast acceleration and deceleration even at high speeds. This reduces the cycle time of your equipment and increases productivity.
Energy Saving
Power loss has been reduced by 10% compared to the conventional product,* making your equipment more energy efficient.
The motor's low heat generation keeps thermal expansion low,
consistently providing high precision.
* Conventional product: Flat type linear servo motor with core (model no.: DS045CC1AN)
■Specifications
Rated thrust [N] |
Max. thrust [N] |
Rated speed [m/s] |
Max. speed [m/s] |
Magnetic attraction force [N] |
Mover mass [kg] |
Compatible magnet rail model no. |
340 |
630 |
2.0 |
3.0 |
2000 |
2.15 |
DS050MD□□□ |
DS050CD1AN RS3A03
Magnet rail model no.
N2
Magnet rail mass [kg] |
Dimensions [mm] |
||
L1 |
L2 |
N1 |
|
0.22 |
64 |
32 |
1 |
0.45 |
128 |
96 |
3 |
0.9 |
256 |
224 |
7 |
1.8 |
512 |
480 |
15 |
DS050MD064 4 DS050MD128 8 DS050MD256 16 DS050MD512 32
Thrust-Speed Characteristics
Max. thrust Rated thrust Max. speed Rated speed |
Dual Magnet type[with core]
Flat type[with core]
Center Magnet type[with core]
Compact linear servo motors with large thrust.
Contact us for the model number of compatible amplifiers.
■How to read model numbers
Note that not all the possible combinations of the numbers and characters below are valid. Also, some of the numbers/characters listed below are for optional models.
System ConfigurationAnalog/Pulse Input type
T S R
Molded case circuit breaker (MCCB)
Used to protect the power line.
Cuts off power in case of an overload.
Servo amplifier
Noise filter
Attached to prevent external noise from the power source line.
Electromagnetic contactor
Option
Setup software
Parameter setting and monitoring are possible via communication with a PC.
External regenerative resistorThough a built-in regenerative resistor is sufficient for normal operation, use an external regenerative resistor for more capacity in such a case of high-frequency operation.
■Connector to connect servo amplifier
10 to 50 A
Individual connectors and ServoM
List of Com
Servo Am
Connector no.Manufacturer
Item |
Model no. |
Manufacturer model no. |
For controller connection |
AL-00385594 |
10150-3000PE and 10350-52A0-008 |
For linear encoder and hall sensor connections |
AL-00632607 |
36210-0100PL and 36310-3200-008 |
For input power supply and regenerative resistor connections |
AL-00686902-01 |
MSTBT2.5/8-STF-5.08LUB |
For linear motor connection |
AL-Y0004079-01 |
MSTBT2.5/3-STF-5.08 |
For safety device connection (for short-circuiting) |
AL-00849548-02 |
1971153-2 |
For safety device connection (for wiring) |
AL-00718252-01 |
2013595-3 |
CNB
CN4 (2)Tyco Electronics Japan G.K. CN4
(1) Amplifiers with built-in regenerative resistor are equipped with a CNA connector.
(2) When CN4 is not wired, be sure to insert a safety device connector (for short-circuiting) to CN4 on the servo amplifier.Analog/Pulse
Connector sets (For non-STO models)
No
Built-in regenerative resistor |
No |
Yes |
No |
Yes |
No/Yes |
No/Yes |
AL-00723282 |
AL-00723284 |
AL-00723286 |
AL-00723288 |
AL-00723290 |
AL-00781940 |
|
CN1: For controller connection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
EN1: For encoder connection |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
EN2: For encoder connection |
No |
No |
Yes |
Yes |
No |
Yes |
CNA: For input power supply and regenerative resistor connections |
Yes |
No |
Yes |
No |
No |
No |
CNB: For servo motor connection |
Yes |
Yes |
Yes |
Yes |
No |
No |
CN4: For safety device connection (for short-circuiting) |
No |
No |
No |
No |
No |
No |
CN4: For safety device connection (for wiring) |
No |
No |
No |
No |
No |
No |
With hall sensor |
With hall sensor |
System ConfigurationEtherCAT interface type
T S R
Molded case circuit breaker (MCCB)
Used to protect the power line.
Cuts off power in case of an overload.
Servo amplifier
Noise filter
Attached to prevent external noise from the power source line.
Electromagnetic contactor
Option
Setup software Parameter setting and monitoring are possible via communication with a PC.