Ultra-Mini ELECYLINDER®
EC-SL3
EC-GDS3/GDB3
EC-T3
Built-in controller
Believe it:
A built-in controller at this size!
Ultra-Mini ELECYLINDER® EC-T3
The following uses are available
Application Example: Indexing table connector assembly equipment
- Transport/assembly
- Setting/cutting out
- Insertion
- Cutting out
Select from three types according to the application
Type | Slider | Rod | Table |
Products | EC-SL3 | EC-GDS3/GDB3 | EC-T3 |
Max. speed | 200 mm/s | 200 mm/s | 200 mm/s |
Max. push force | 16N | 17N | 17N |
Max. payload [Horizontal/vertical] |
2 kg/0.7 kg | 2 kg/0.8 kg | 2 kg/0.8 kg |
*Vertical only for GDS3
The Ultra-Mini ELECYLINDER
resolves all kinds of small air cylinder problems!
Problem: Speed adjustment is difficult with small cylinders...
Problem Solved! ELECYLINDER speed can beset easilyat any value needed, from low speed to high-speed operation
Features
- Teaching pendant (TB-03)
- Speed can be set with numbers from 1% (low speed) to 100% (high speed), enabling the same motion regardless of the operator.
Problem: Water builds up too fast in the drain...
Problem solved! The ELECYLINDER is electric and thusairless
What's more, it is anall-in-onemachine with controller and guide built-in
Features
- Controller
- Encoder
- Motor built-in
- Ball circulating type with a built-in linear guide
- Design is easy with all the necessary components already assembled.
Problem: The whole cylinder has to be replaced when the packing or stopper breaks...
Problem solved! The Ultra-Mini ELECYLINDER has a life of five million cycles (For vertical mounting)
What's more,maintenanceissimple
Features
- Slider type
- Motor + controller unit (common)
- Rod type
- Table type
- Mounting
- Modular structure makes replacement easy.
Introducing the functions made possible byELECYLINDER
◆Status shown by body LEDs
LEDs on the body clarify the operation status.
With forward end/backward end display added, the status is clear at a glance.
- LED left
- LED right
- Servo ON
- Backward end
- Alarm
LED left |
LED right |
Color |
Operation status |
⬤ |
⬤ |
Orange |
Initializing at power ON |
× |
× |
— |
Power OFF |
Servo OFF |
|||
★ |
× |
Green |
Wirelessly connected |
× |
⬤ |
Green |
Servo ON |
⬤ |
× |
Orange |
Backward end [LS0]* |
× |
⬤ |
Orange |
Forward end [LS1]* |
× |
⬤ |
Red |
Alarm |
× |
Stopped for emergency |
⬤: Lit ×: Off★: Blinking *Display is possible with parameter switching
◆Simple operation with wireless connection
The teaching pendant (TB-03) can be connected wirelessly to an ELECYLINDER within a 5m radius. This enables status confirmation, position/speed setting, test runs and so on.
Teaching pendant
(TB-03)
◆Multi-axis control and network connection with RCON-EC connection specification
Use of the ELECYLINDER dedicated drive unit REC enables connection with up to 16 axes, reducing wiring and saving control panel space.
For the RCON-ECconnection specification, see theR-unit catalog
Model Specification Items
ELECYLINDER®
ECSeries
Type
SL3 |
Slider type (base width 32mm) |
GDS3 |
Rod type with rolling bushing (width 42mm) |
GDB3 |
Rod type with ball bearing (width 42mm) |
T3 |
Table type (table width 32mm) |
(Note) Only lead 2 is available for GDS3.
Lead
L |
Lead 2mm |
M |
Lead 4mm |
Stroke
<SL3>
50 |
50mm |
~ |
~ |
200 |
200mm |
(every 25mm)
<GDS3>
10 |
10mm |
~ |
~ |
30 |
30mm |
(every 10mm)
<GDB3>
10 |
10mm |
~ |
~ |
50 |
50mm |
(every 10mm)
<T3>
10 |
10mm |
~ |
~ |
50 |
50mm |
(every 10mm)
Actuator cable length
1 |
1m |
~ |
~ |
10 |
10m |
(Note) When using the interface box, 9m is the maximum available.
Power I/O cable connector length
0 |
No cable Power / I/O connector included(Note 1) |
(S)1 |
1m |
~ |
~ |
(S)9 |
9m |
(every 1m)
(S) 4-way connector cable
(Note) Make sure that the total length along with the actuator cable is 10m or less.
(Note 1) W h e n s e l e c t i n g R C O N - E C connection specification (ACR), select "0." Power / I/O connector is not included.
Options
Left blank |
NPN specification (interface box connection), no options |
ACR |
RCON-EC connection specification(Note 2) (Note 3) |
B |
Brake specification |
CJB |
Cable exit direction specification (bottom) |
CJL |
Cable exit direction specification (left) |
CJR |
Cable exit direction specification (right) |
CJT |
Cable exit direction specification (top) |
NM |
Non-motor end specification |
PN |
PNP specification (interface box connection)(Note 2) |
TMD2 |
Split motor and controller power specification (interface box connection)(Note 2) |
WL |
Wireless communication specification (interface box connection)(Note 3) |
WL2 |
Wireless communication axis operation specification (interface box connection)(Note 3) |
(Note 2) "PN" and "TMD2" cannot be selected when "ACR" is selected.
(Note 3) "WL" and "WL2" cannot be selected when "ACR" is selected.
(When using wireless communication, an interface box and cable must be provided separately.)
*Please refer to the reference page of each type for details.
Specification Tables
Slider
Product type |
Type |
Lead |
Stroke (mm) and max speed (mm/s) *Length of band = Stroke; *Numbers in band = Maximum speed by stroke |
Max. payload (kg) |
Reference Page |
||||||||
Model |
mm |
Horizontal |
Vertical |
||||||||||
50 |
75 |
100 |
125 |
150 |
175 |
200 |
|||||||
Slider |
SL3 |
M- L- |
4 2 |
200 100 |
1 2 |
0.3 0.7 |
P7 |
Rod
Product type |
Type |
Lead |
Stroke (mm) and max speed (mm/s) *Length of band = Stroke; *Numbers in band = Maximum speed by stroke |
Max. push force (N) |
Max. payload (kg) |
Reference Page |
||||||
Model |
mm |
Horizontal |
Vertical |
|||||||||
10 |
20 |
30 |
40 |
50 |
||||||||
Rod |
GDS3 |
L- |
2 |
100 |
17 |
- |
0.8 |
P11 |
||||
GDB3 |
M- L- |
4 2 |
200 100 |
10 17 |
1 2 |
0.4 0.8 |
P15 |
Table
Product type |
Type |
Lead |
Stroke (mm) and max speed (mm/s) *Length of band = Stroke; *Numbers in band = Maximum speed by stroke |
Max. push force (N) |
Max. payload (kg) |
Reference Page |
||||||
Model |
mm |
Horizontal |
Vertical |
|||||||||
10 |
20 |
30 |
40 |
50 |
||||||||
Table |
T3 |
M- L- |
4 2 |
200 100 |
10 17 |
1 2 |
0.4 0.8 |
P19 |
Mounting Orientation
🞅: Can be mounted ×: Cannot be mounted
Mounting orientation |
|||||
Series |
Type |
Horizontal mounting on fl at surface |
Vertical mounting (Note 1) |
Horizontal mounting to side |
Horizontal mounting suspended |
EC |
SL3 |
🞅 |
🞅 |
🞅(Note 2) |
🞅(Note 2) |
GDS3 |
× |
🞅 |
× |
× |
|
GDB3 |
🞅 |
🞅 |
🞅 |
🞅 |
|
T3 |
🞅 |
🞅 |
🞅 |
🞅 |
(Note 1) When mounting vertically, be sure to install the motor on the top. Installing with the motor on the bottom could cause grease to separate and base oil to leak into the motor, which could cause controller or motor encoder failure. It is therefore not recommended to install the motor on the bottom side.
(Note 2) Installing the product horizontal to side or horizontally ceiling mounted may cause slack or misalignment in the stainless steel sheet, so inspect regularly and adjust as needed. (Note) Keep the body installation surface and workpiece mounting surface flatness and straightness at or below the values below.
Type |
Body installation surface |
Workpiece mounting surface |
||
Flatness |
Straightness |
Flatness |
Straightness |
|
SL3 |
0.02mm/m or less |
0.01mm or less |
0.02mm/m or less |
— |
GDS3 GDB3 |
— |
— |
||
T3 |
— |
0.01mm or less |
If the body installation surface and workpiece mounting surface flatness and straightness do not satisfy the figures above, the sliding resistance will increase, leading to malfunctions.
Mounting Methods
Mount according to the mounting method for the applicable type.
Slider type (SL3)
⬤Using base bottom surface screw hole *Be careful, as the screw depth will
interfere with the interior components if it exceeds 6mm.
⬤Using base interior counterbored hole *The stainless steel sheet must be removed during the process.Hex socket bolt interfere with the interior components if it exceeds 6mm.
Rod type (GDS3/GDB3)
⬤Using body top surface through hole
⬤Using body bottom surface screw hole
⬤Using body side surface screw hole
Table type (T3)
⬤When fixing from body top surface
⬤Using body bottom surface mounting hole
ECELECYLINDER®
EC-SL3
- Coupled Motor
- Body Width 30mm
- 24V Stepper Motor
- Lead Screw
■Model Specification Items
Series:
EC - SL3
Type |
Lead |
|
M |
4mm |
|
L |
2mm |
Stroke |
|
50~ 200 |
50mm~ 200mm (every 25mm) |
Actuator cable length |
See actuator cable length table below |
Power I/O cable connector length |
See power I/O cable connector length table below |
Options |
See options below |
■Stroke
Stroke (mm) |
RCON-EC connection specification (Note 1) |
NPN/PNP specifications |
50 |
🞅 |
🞅 |
75 |
🞅 |
🞅 |
100 |
🞅 |
🞅 |
125 |
🞅 |
🞅 |
150 |
🞅 |
🞅 |
175 |
🞅 |
🞅 |
200 |
🞅 |
🞅 |
(Note 1) Be sure to select “ACR” as an option.
■Options* Please check the Options reference pages to confirm each option.
Name |
Option code |
Reference page |
RCON-EC connection specification (Note 2) (Note 3) |
ACR |
23 |
Brake |
B |
23 |
Cable exit direction (bottom) |
CJB |
23 |
Cable exit direction (left) |
CJL |
23 |
Cable exit direction (right) |
CJR |
23 |
Cable exit direction (top) |
CJT |
23 |
Non-motor end specification |
NM |
23 |
PNP specification (Note 2) |
PN |
23 |
Split motor and controller power supply specification (Note 2) |
TMD2 |
23 |
Wireless communication specification (Note 3) |
WL |
23 |
Wireless axis operation specification (Note 3) |
WL2 |
23 |
(Note 2) If the RCON-EC connection specification (ACR) is selected, the PNP specification (PN) and split motor and controller power supply specification (TMD2) cannot be selected. As well, the interface box and conversion cable are not included.
(Note 3)When selecting the RCON-EC connection specification (ACR), the wireless communication specification (WL) and wireless axis operation supported specification (WL2) cannot be selected. When using wireless communication with RCON-EC connection, separately prepare the interface box, conversion cable, and power / I/O cable connector which are available as options. Please refer to P. 27 for details.
■Separately Sold Options
Name |
Model |
Reference page |
Interface box conversion cable |
CB-CVN-BJ002 |
32 |
RCON-EC connection specification power / I/O cable (standard connector cable) |
CB-REC PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification power / I/O cable (4-way connector cable) |
CB-REC2- PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification interface box for split motor and controller power supply (wireless specification) |
ECW-CVNWL-CB ACR |
32 |
(Note) The power / I/O cable connector is a robot cable.
Please indicate the cable length in⬜⬜⬜. (Ex.: 010 = 1m)
EC-SL3
Selection Notes |
(1) “Main Specifications” displays the payload’s maximum value. Please refer to “Table of Payload by Speed/Acceleration” for more details. (2) If performing push-motion operations, refer to the “Correlation Diagrams between Push Force and Current Limit.” The push forces listed are only reference values. Please refer to P. 26 for applicable notes. (3) Pay close attention to the mounting orientation. Refer to P. 5 for details. (4) Reference value of the overhang load length is under 100mm in the Ma, Mb, and Mc directions. Please refer to the explanation on P. 26 for the overhang load length. (5) The center mass location of the attached object should be less than 1/2 of the overhang distance. Operating conditions should be moderated if abnormal vibration or noise is observed, even if the overhang distance and load moment are within allowable values. |
■Actuator Cable Length
Cable code |
Cable length |
Actuator cable length |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 10 |
6 ~ 10m (Note 4) |
🞅 |
(Note 4) When connecting via the interface box, 9m is the maximum available. (Note) Make sure that the total length along with the power I/O cable connector is 10m or less.
■Power I/O Cable Connector Length
■Standard Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC-PWBIO⬜⬜⬜-RB supplied |
||
0 |
Without cable |
🞅(Note 5) |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 7 |
6 ~ 7m |
🞅 |
8 ~ 9 |
8 ~ 9m |
🞅 |
(Note 5) Only terminal block connector is included. When selecting RCON-EC connection specification (ACR) as an option, select “0.” Terminal block connector is not included. Refer to P. 30 for details.
(Note) Robot cable.
■4-way Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC2-PWBIO⬜⬜⬜-RB supplied |
||
S1 ~ S3 |
1 ~ 3m |
🞅 |
S4 ~ S5 |
4 ~ 5m |
🞅 |
S6 ~ S7 |
6 ~ 7m |
🞅 |
S8 ~ S9 |
8 ~ 9m |
🞅 |
(Note) Robot cable.
■Main Specifications
Item |
Description |
|||
Lead |
Ball screw lead (mm) |
4 |
2 |
|
Horizontal |
Payload |
Max. payload (kg) |
1 |
2 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
200 |
100 |
|
Min. speed (mm/s) |
20 |
10 |
||
Rated acceleration/deceleration (G) |
0.5 |
0.3 |
||
Max. acceleration/deceleration (G) |
0.5 |
0.3 |
||
Vertical |
Payload |
Max. payload (kg) |
0.3 |
0.7 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
200 |
100 |
|
Min. speed (mm/s) |
20 |
10 |
||
Rated acceleration/deceleration (G) |
0.5 |
0.3 |
||
Max. acceleration/deceleration (G) |
0.5 |
0.3 |
||
Push |
Max. push force (N) |
9 |
16 |
|
Max. push speed (mm/s) |
20 |
20 |
||
Brake |
Brake specification |
Non-excitation actuating solenoid brake |
||
Brake holding force (kgf) |
0.3 |
0.7 |
||
Stroke |
Min. stroke (mm) |
50 |
50 |
|
Max. stroke (mm) |
200 |
200 |
||
Stroke pitch (mm) |
25 |
25 |
Item |
Description |
Drive system |
Rolling screwφ4mm, rolled C10 |
Positioning repeatability |
±0.05mm |
Lost motion |
- (notation not available due to 2-point positioning function) |
Base |
Dedicated aluminum extruded material (A6063SS-T5 equivalent), black alumite treatment |
Linear guide |
Linear motion infinite circulating type |
Allowable static moment |
Ma: 11.7N·m |
Mb: 11.7N·m |
|
Mc: 22.0N·m |
|
Allowable dynamic moment (Note 6) |
Ma: 4.71N·m |
Mb: 4.71N·m |
|
Mc: 8.84N·m |
|
Ambient operating temperature, humidity |
0 ~ 40°C, 85%RH or less (no condensation) |
Ingress protection |
IP20 |
Vibration & shock resistance |
4.9m/s2 |
Overseas standards |
CE marking, RoHS directive |
Motor type |
Stepper motor (φ20) |
Encoder type |
Incremental |
Number of encoder pulses |
32768 pulse/rev |
(Note 6) Based on the standard rated operation life of 5,000km. Operation life varies according to operating and mounting conditions. Please refer to General Catalog 2021 P. 1-244 for details on operation life.
■Slider Type Moment Direction
■Table of Payload by Speed/Acceleration
The unit for payload is kg.
Lead 4
Orientation |
Horizontal |
Vertical |
Speed (mm/s) |
Acceleration (G) |
|
0.5 |
0.5 |
|
0 |
1 |
0.3 |
100 |
1 |
0.3 |
150 |
1 |
0.3 |
200 |
1 |
0.3 |
Lead 2
Orientation |
Horizontal |
Vertical |
Speed (mm/s) |
Acceleration (G) |
|
0.3 |
0.3 |
|
0 |
2 |
0.7 |
20 |
2 |
0.7 |
50 |
2 |
0.7 |
100 |
2 |
0.7 |
■Stroke and Max. Speed
Lead (mm) |
50 (mm) |
75 (mm) |
100 (mm) |
125 (mm) |
150 (mm) |
175 (mm) |
200 (mm) |
4 |
200 <200> |
||||||
2 |
100 <100> |
(Note) When the slider is returning to its home position, please be careful of interference from surrounding objects, as it will travel until it reaches the M.E. (Note) Fix the cable so that its base does not move.
■Dimensions by Stroke
Stroke |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
|
L(Note 8) |
Without brake |
189 |
214 |
239 |
264 |
289 |
314 |
339 |
With brake |
214 |
239 |
264 |
289 |
314 |
339 |
364 |
|
A |
129.5 |
154.5 |
179.5 |
204.5 |
229.5 |
254.5 |
279.5 |
|
B |
117 |
142 |
167 |
192 |
217 |
242 |
267 |
|
C |
50 |
100 |
100 |
100 |
100 |
100 |
100 |
|
D |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
E |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
|
F |
50 |
100 |
100 |
100 |
100 |
100 |
100 |
|
G |
1 |
1 |
1 |
1 |
1 |
2 |
2 |
|
H |
4 |
4 |
4 |
4 |
4 |
6 |
6 |
|
J |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
(Note 8) When selecting cable exit direction (option), 1 is subtracted from the dimensions.
■Mass by Stroke
Stroke |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
|
Mass (kg) |
Without brake |
0.25 |
0.28 |
0.31 |
0.32 |
0.35 |
0.37 |
0.40 |
With brake |
0.27 |
0.30 |
0.33 |
0.34 |
0.37 |
0.39 |
0.42 |
■Applicable Controllers
(Note) EC Series products are equipped with a built-in controller. Please refer to P. 28 for details on built-in controllers.
EC-GDS3
EC-GDS3 L
■Model Specification Items
- Body Width 40mm
- CoupledMotor
- Lead Screw
- 24V Stepper Motor
Series
Type |
Lead |
|
L |
2mm |
Stroke |
|
10~ 30 |
10mm~ 30mm (every 10mm) |
Actuator cable length |
See actuator cable length table below |
Power I/O cable connector length |
See power I/O cable connector length table below |
Options |
See options below |
Selection Notes |
(1) “Main Specifications” displays the payload’s maximum value. Please refer to “Table of Payload by Speed/Acceleration” for more details. (2) If performing push-motion operations, refer to the “Correlation Diagrams between Push Force and Current Limit.” The push forces listed are only reference values. Please refer to P. 26 for applicable notes. (3) Pay close attention to the mounting orientation. Please refer to P. 5 for details. (4) Recommended for use in stopper applications. Refer to the instruction manual for the usage range. |
■Stroke
Stroke (mm) |
RCON-EC connection specification (Note 1) |
NPN/PNP specifications |
10 |
🞅 |
🞅 |
20 |
🞅 |
🞅 |
30 |
🞅 |
🞅 |
(Note 1) Be sure to select “ACR” as an option.
■Options
* Please check the Options reference pages to confirm each option.
Name |
Option code |
Reference page |
RCON-EC connection specification (Note 2) (Note 3) |
ACR |
23 |
Brake |
B |
23 |
Cable exit direction (bottom) |
CJB |
23 |
Cable exit direction (left) |
CJL |
23 |
Cable exit direction (right) |
CJR |
23 |
Cable exit direction (top) |
CJT |
23 |
Non-motor end specification |
NM |
23 |
PNP specification (Note 2) |
PN |
23 |
Split motor and controller power supply specification (Note 2) |
TMD2 |
23 |
Wireless communication specification (Note 3) |
WL |
23 |
Wireless axis operation specification (Note 3) |
WL2 |
23 |
(Note 2) If the RCON-EC connection specification (ACR) is selected, the PNP specification (PN) and split motor and controller power supply specification (TMD2) cannot be selected. As well, the interface box and conversion cable are not included.
(Note 3)When selecting the RCON-EC connection specification (ACR), the wireless communication specification (WL) and wireless axis operation supported specification (WL2) cannot be selected. When using wireless communication with RCON-EC connection, separately prepare the interface box, conversion cable, and power / I/O cable connector which are available as options. Please refer to P. 27 for details.
■Separately Sold Options
Name |
Model |
Reference page |
Interface box conversion cable |
CB-CVN-BJ002 |
32 |
RCON-EC connection specification power / I/O cable (standard connector cable) |
CB-REC PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification power / I/O cable (4-way connector cable) |
CB-REC2- PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification interface box for split motor and controller power supply (wireless specification) |
ECW-CVNWL-CB ACR |
32 |
(Note) The power / I/O cable connector is a robot cable.
Please indicate the cable length in⬜⬜⬜. (Ex.: 010 = 1m)
■Actuator Cable Length
Cable code |
Cable length |
Actuator cable length |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 10 |
6 ~ 10m (Note 4) |
🞅 |
(Note 4) When connecting via the interface box, 9m is the maximum available. (Note) Make sure that the total length along with the power I/O cable connector is 10m or less.
■Power I/O Cable Connector Length
■Standard Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC-PWBIO⬜⬜⬜-RB supplied |
||
0 |
Without cable |
🞅(Note 5) |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 7 |
6 ~ 7m |
🞅 |
8 ~ 9 |
8 ~ 9m |
🞅 |
(Note 5) Only terminal block connector is included. When selecting RCON-EC connection specification (ACR) as an option, select “0.” Terminal block connector is not included. Refer to P. 30 for details.
(Note) Robot cable.
■4-way Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC2-PWBIO⬜⬜⬜-RB supplied |
||
S1 ~ S3 |
1 ~ 3m |
🞅 |
S4 ~ S5 |
4 ~ 5m |
🞅 |
S6 ~ S7 |
6 ~ 7m |
🞅 |
S8 ~ S9 |
8 ~ 9m |
🞅 |
(Note) Robot cable.
■Main Specifications
Item |
Description |
||
Lead |
Ball screw lead (mm) |
2 |
|
Vertical |
Payload |
Max. payload (kg) |
0.8 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
100 |
|
Min. speed (mm/s) |
10 |
||
Rated acceleration/deceleration (G) |
0.3 |
||
Max. acceleration/deceleration (G) |
0.3 |
||
Push |
Max. push force (N) |
17 |
|
Max. push speed (mm/s) |
20 |
||
Brake |
Brake specification |
Non-excitation actuating solenoid brake |
|
Brake holding force (kgf) |
0.8 |
||
Stroke |
Min. stroke (mm) |
10 |
|
Max. stroke (mm) |
30 |
||
Stroke pitch (mm) |
10 |
Item |
Description |
Drive system |
Rolling screw φ4mm, rolled C10 |
Positioning repeatability |
±0.05mm |
Lost motion |
- (notation not available due to 2-point positioning function) |
Rod non-rotation precision |
- |
Operation life |
Vertical 5 million operating cycles |
Ambient operating temperature, humidity |
0 ~ 40°C, 85%RH or less (no condensation) |
Ingress protection |
IP20 |
Vibration & shock resistance |
4.9m/s2 |
Overseas standards |
CE marking, RoHS directive |
Motor type |
Stepper motor (φ20) |
Encoder type |
Incremental |
Number of encoder pulses |
32768 pulse/rev |
■Table of Payload by Speed/Acceleration
The unit for payload is kg.
Lead 2
Orientation |
Vertical |
Speed (mm/s) |
Acceleration (G) |
0.3 |
|
0 |
0.8 |
30 |
0.8 |
70 |
0.8 |
100 |
0.8 |
■Stroke and Max. Speed
Lead (mm) |
10 (mm) |
20 (mm) |
30 (mm) |
2 |
100 |
(Note) When returning to the home position, the rod will move to the M.E. Be careful of interference with surrounding objects. (Note) Fix the cable so that its base does not move.
The cable can be separated and replaced. (Connected to the connector in the cable box)
The cable exit direction (option) can be changed by changing the cable box direction.
■Dimensions by Stroke
Stroke |
10 |
20 |
30 |
|
L(Note 7) |
Without brake |
97 |
107 |
117 |
With brake |
122 |
132 |
142 |
|
B |
28 |
38 |
48 |
|
C |
10 |
20 |
30 |
|
F |
0 |
10 |
20 |
|
H |
2 |
4 |
4 |
|
J |
0 |
10 |
20 |
(Note 7) When selecting cable exit direction (option), 1 is subtracted from the dimensions.
■Mass by Stroke
Stroke |
10 |
20 |
30 |
|
Mass (kg) |
Without brake |
0.15 |
0.17 |
0.19 |
With brake |
0.17 |
0.19 |
0.21 |
■Applicable Controllers
(Note) EC Series products are equipped with a built-in controller. Please refer to P. 28 for details on built-in controllers.
EC-GDS3
■Model Specification Items
EC - GDB3Series
Type |
Lead |
|
M |
4mm |
|
L |
2mm |
Stroke |
|
10~ 50 |
10mm~ 50mm (every 10mm) |
Actuator cable length |
See actuator cable length table below |
Power I/O cable connector length |
See power I/O cable connector length table below |
Options |
See options below |
■Stroke
Stroke (mm) |
RCON-EC connection specification (Note 1) |
NPN/PNP specifications |
10 |
🞅 |
🞅 |
20 |
🞅 |
🞅 |
30 |
🞅 |
🞅 |
40 |
🞅 |
🞅 |
50 |
🞅 |
🞅 |
(Note 1) Be sure to select “ACR” as an option.
■Options
* Please check the Options reference pages to confirm each option.
Name |
Option code |
Reference page |
RCON-EC connection specification (Note 2) (Note 3) |
ACR |
23 |
Brake |
B |
23 |
Cable exit direction (bottom) |
CJB |
23 |
Cable exit direction (left) |
CJL |
23 |
Cable exit direction (right) |
CJR |
23 |
Cable exit direction (top) |
CJT |
23 |
Non-motor end specification |
NM |
23 |
PNP specification (Note 2) |
PN |
23 |
Split motor and controller power supply specification (Note 2) |
TMD2 |
23 |
Wireless communication specification (Note 3) |
WL |
23 |
Wireless axis operation specification (Note 3) |
WL2 |
23 |
(Note 2) If the RCON-EC connection specification (ACR) is selected, the PNP specification (PN) and split motor and controller power supply specification (TMD2) cannot be selected. As well, the interface box and conversion cable are not included.
(Note 3)When selecting the RCON-EC connection specification (ACR), the wireless communication specification (WL) and wireless axis operation supported specification (WL2) cannot be selected. When using wireless communication with RCON-EC connection, separately prepare the interface box, conversion cable, and power / I/O cable connector which are available as options. Please refer to P. 27 for details.
■Separately Sold Options
Name |
Model |
Reference page |
Interface box conversion cable |
CB-CVN-BJ002 |
32 |
RCON-EC connection specification power / I/O cable (standard connector cable) |
CB-REC PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification power / I/O cable (4-way connector cable) |
CB-REC2- PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification interface box for split motor and controller power supply (wireless specification) |
ECW-CVNWL-CB ACR |
32 |
(Note) The power / I/O cable connector is a robot cable.
Please indicate the cable length in⬜⬜⬜. (Ex.: 010 = 1m)
Selection Notes |
(1) “Main Specifications” displays the payload’s maximum value. Please refer to “Table of Payload by Speed/Acceleration” for more details. (2) If performing push-motion operations, refer to the “Correlation Diagrams between Push Force and Current Limit.” The push forces listed are only reference values. Please refer to P. 26 for applicable notes. (3) Pay close attention to the mounting orientation. Please refer to P. 5 for details. (4) When radial and moment loads are applied to the rod, refer to the instruction manual. (5) Cannot be used for stopper applications. |
■Actuator Cable Length
Cable code |
Cable length |
Actuator cable length |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 10 |
6 ~ 10m (Note 4) |
🞅 |
(Note 4) When connecting via the interface box, 9m is the maximum available. (Note) Make sure that the total length along with the power I/O cable connector is 10m or less.
■Power I/O Cable Connector Length
■Standard Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC-PWBIO⬜⬜⬜-RB supplied |
||
0 |
Without cable |
🞅(Note 5) |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 7 |
6 ~ 7m |
🞅 |
8 ~ 9 |
8 ~ 9m |
🞅 |
(Note 5) Only terminal block connector is included. When selecting RCON-EC connection specification (ACR) as an option, select “0.” Terminal block connector is not included. Refer to P. 30 for details.
(Note) Robot cable.
■4-way Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC2-PWBIO⬜⬜⬜-RB supplied |
||
S1 ~ S3 |
1 ~ 3m |
🞅 |
S4 ~ S5 |
4 ~ 5m |
🞅 |
S6 ~ S7 |
6 ~ 7m |
🞅 |
S8 ~ S9 |
8 ~ 9m |
🞅 |
(Note) Robot cable.
■Main Specifications
Item |
Description |
|||
Lead |
Ball screw lead (mm) |
4 |
2 |
|
Horizontal |
Payload |
Max. payload (kg) |
1 |
2 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
200 |
100 |
|
Min. speed (mm/s) |
20 |
10 |
||
Rated acceleration/deceleration (G) |
0.5 |
0.3 |
||
Max. acceleration/deceleration (G) |
0.5 |
0.3 |
||
Vertical |
Payload |
Max. payload (kg) |
0.4 |
0.8 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
200 |
100 |
|
Min. speed (mm/s) |
20 |
10 |
||
Rated acceleration/deceleration (G) |
0.5 |
0.3 |
||
Max. acceleration/deceleration (G) |
0.5 |
0.3 |
||
Push |
Max. push force (N) |
10 |
17 |
|
Max. push speed (mm/s) |
20 |
20 |
||
Brake |
Brake specification |
Non-excitation actuating solenoid brake |
||
Brake holding force (kgf) |
0.4 |
0.8 |
||
Stroke |
Min. stroke (mm) |
10 |
10 |
|
Max. stroke (mm) |
50 |
50 |
||
Stroke pitch (mm) |
10 |
10 |
Item |
Description |
Drive system |
Rolling screwφ4mm, rolled C10 |
Positioning repeatability |
(10ST) ±0.1mm, (20ST or higher) ±0.05mm |
Lost motion |
- (notation not available due to 2-point positioning function) |
Rod non-rotation precision |
- |
Operation life |
Horizontal 10 million operating cycles, vertical 5 million operating cycles |
Ambient operating temperature, humidity |
0 ~ 40°C, 85%RH or less (no condensation) |
Ingress protection |
IP20 |
Vibration & shock resistance |
4.9m/s2 |
Overseas standards |
CE marking, RoHS directive |
Motor type |
Stepper motor (φ20) |
Encoder type |
Incremental |
Number of encoder pulses |
32768 pulse/rev |
■Table of Payload by Speed/Acceleration
The unit for payload is kg.
Lead 4
Orientation |
Horizontal |
Vertical |
Speed (mm/s) |
Acceleration (G) |
|
0.5 |
0.5 |
|
0 |
1 |
0.4 |
50 |
1 |
0.4 |
100 |
1 |
0.4 |
200 |
1 |
0.4 |
Lead 2
Orientation |
Horizontal |
Vertical |
Speed (mm/s) |
Acceleration (G) |
|
0.3 |
0.3 |
|
0 |
2 |
0.8 |
30 |
2 |
0.8 |
70 |
2 |
0.8 |
100 |
2 |
0.8 |
■Stroke and Max. Speed
Lead (mm) |
10 (mm) |
20 (mm) |
30 (mm) |
40 (mm) |
50 (mm) |
4 |
200 <200> |
||||
2 |
100 <100> |
(Unit: mm/s)
(Note) Values in brackets < > are for vertical use.
■Dimensions by Stroke
Stroke |
10 |
20 |
30 |
40 |
50 |
|
L (Note 7) |
Without brake |
97 |
107 |
117 |
127 |
137 |
With brake |
122 |
132 |
142 |
152 |
162 |
|
B |
28 |
38 |
48 |
58 |
68 |
|
C |
10 |
20 |
30 |
40 |
50 |
|
F |
0 |
10 |
20 |
30 |
40 |
|
H |
2 |
4 |
4 |
4 |
4 |
|
J |
0 |
10 |
20 |
30 |
40 |
(Note 7) When selecting cable exit direction (option), 1 is subtracted from the dimensions.
■Mass by Stroke
Stroke |
10 |
20 |
30 |
40 |
50 |
|
Mass (kg) |
Without brake |
0.14 |
0.17 |
0.19 |
0.21 |
0.23 |
With brake |
0.16 |
0.19 |
0.21 |
0.23 |
0.25 |
■Applicable Controllers
(Note) EC Series products are equipped with a built-in controller. Please refer to P. 28 for details on built-in controllers.
■Model Specification Items
EC - T3
Series
T3 |
||
Type |
Lead |
|
M |
4mm |
|
L |
2mm |
Stroke |
|
10~ 50 |
10mm~ 50mm (every 10mm) |
Actuator cable length |
See actuator cable length table below |
Power I/O cable connector length |
See power I/O cable connector length table below |
Options |
See options below |
■Stroke
Stroke (mm) |
RCON-EC connection specification (Note 1) |
NPN/PNP specifications |
10 |
🞅 |
🞅 |
20 |
🞅 |
🞅 |
30 |
🞅 |
🞅 |
40 |
🞅 |
🞅 |
50 |
🞅 |
🞅 |
(Note 1) Be sure to select “ACR” as an option.
■Options
* Please check the Options reference pages to confirm each option.
Name |
Option code |
Reference page |
RCON-EC connection specification (Note 2) (Note 3) |
ACR |
23 |
Brake |
B |
23 |
Cable exit direction (bottom) |
CJB |
23 |
Cable exit direction (left) |
CJL |
23 |
Cable exit direction (right) |
CJR |
23 |
Cable exit direction (top) |
CJT |
23 |
Non-motor end specification |
NM |
23 |
PNP specification (Note 2) |
PN |
23 |
Split motor and controller power supply specification (Note 2) |
TMD2 |
23 |
Wireless communication specification (Note 3) |
WL |
23 |
Wireless axis operation specification (Note 3) |
WL2 |
23 |
(Note 2) If the RCON-EC connection specification (ACR) is selected, the PNP specification (PN) and split motor and controller power supply specification (TMD2) cannot be selected. As well, the interface box and conversion cable are not included.
(Note 3)When selecting the RCON-EC connection specification (ACR), the wireless communication specification (WL) and wireless axis operation supported specification (WL2) cannot be selected. When using wireless communication with RCON-EC connection, separately prepare the interface box, conversion cable, and power / I/O cable connector which are available as options. Please refer to P. 27 for details.
■Separately Sold Options
Name |
Model |
Reference page |
Interface box conversion cable |
CB-CVN-BJ002 |
32 |
RCON-EC connection specification power / I/O cable (standard connector cable) |
CB-REC PWBIO⬜⬜⬜-RB |
33 |
RCON-EC connection specification power / I/O cable (4-way connector cable) |
CB-REC2- PWBIO⬜⬜⬜-RB |
33 |
Air cylinder compatible mounting plate |
EC-CSB-T3-(stroke) |
24 |
RCON-EC connection specification interface box for split motor and controller power supply (wireless specification) |
ECW-CVNWL-CB ACR |
32 |
(Note) The power / I/O cable connector is a robot cable.
Please indicate the cable length in⬜⬜⬜. (Ex.: 010 = 1m)
Selection Notes |
(1) “Main Specifications” displays the payload’s maximum value. Please refer to “Table of Payload by Speed/Acceleration” for more details. (2) If performing push-motion operations, refer to the “Correlation Diagrams between Push Force and Current Limit.” The push forces listed are only reference values. Please refer to P. 26 for applicable notes. (3) Pay close attention to the mounting orientation. Please refer to P. 5 for details. (4) For the table displacement amount, refer to the instruction manual. |
■Actuator Cable Length
Cable code |
Cable length |
Actuator cable length |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 10 |
6 ~ 10m (Note 4) |
🞅 |
(Note 4) When connecting via the interface box, 9m is the maximum available. (Note) Make sure that the total length along with the power I/O cable connector is 10m or less.
■Power I/O Cable Connector Length
■Standard Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC-PWBIO⬜⬜⬜-RB supplied |
||
0 |
Without cable |
🞅(Note 5) |
1 ~ 3 |
1 ~ 3m |
🞅 |
4 ~ 5 |
4 ~ 5m |
🞅 |
6 ~ 7 |
6 ~ 7m |
🞅 |
8 ~ 9 |
8 ~ 9m |
🞅 |
(Note 5) Only terminal block connector is included. When selecting RCON-EC connection specification (ACR) as an option, select “0.” Terminal block connector is not included. Refer to P. 30 for details.
(Note) Robot cable.
■4-way Connector Cable
Cable code |
Cable length |
User wiring specification (flying leads) |
CB-EC2-PWBIO⬜⬜⬜-RB supplied |
||
S1 ~ S3 |
1 ~ 3m |
🞅 |
S4 ~ S5 |
4 ~ 5m |
🞅 |
S6 ~ S7 |
6 ~ 7m |
🞅 |
S8 ~ S9 |
8 ~ 9m |
🞅 |
(Note) Robot cable.
■Main Specifications
Item |
Description |
|||
Lead |
Ball screw lead (mm) |
4 |
2 |
|
Horizontal |
Payload |
Max. payload (kg) |
1 |
2 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
200 |
100 |
|
Min. speed (mm/s) |
20 |
10 |
||
Rated acceleration/deceleration (G) |
0.5 |
0.3 |
||
Max. acceleration/deceleration (G) |
0.5 |
0.3 |
||
Vertical |
Payload |
Max. payload (kg) |
0.4 |
0.8 |
Speed / acceleration/ deceleration |
Max. speed (mm/s) |
200 |
100 |
|
Min. speed (mm/s) |
20 |
10 |
||
Rated acceleration/deceleration (G) |
0.5 |
0.3 |
||
Max. acceleration/deceleration (G) |
0.5 |
0.3 |
||
Push |
Max. push force (N) |
10 |
17 |
|
Max. push speed (mm/s) |
20 |
20 |
||
Brake |
Brake specification |
Non-excitation actuating solenoid brake |
||
Brake holding force (kgf) |
0.4 |
0.8 |
||
Stroke |
Min. stroke (mm) |
10 |
10 |
|
Max. stroke (mm) |
50 |
50 |
||
Stroke pitch (mm) |
10 |
10 |
Item |
Description |
Drive system |
Rolling screwφ4mm, rolled C10 |
Positioning repeatability |
±0.05mm |
Lost motion |
- (notation not available due to 2-point positioning function) |
Allowable static moment |
Ma: 1.90 N·m (10ST) 5.08 N·m (20ST) 11.7 N·m (30ST or higher) |
Mb: 1.90 N·m (10ST) 5.08 N·m (20ST) 11.7 N·m (30ST or higher) |
|
Mc: 7.99 N·m (10ST) 14.0 N·m (20ST) 22.0 N·m (30ST or higher) |
|
Allowable dynamic moment (Note 6) |
Ma: 1.04 N·m (10ST) 2.35 N·m (20ST) 4.71 N·m (30ST or higher) |
Mb: 1.04 N·m (10ST) 2.35 N·m (20ST) 4.71 N·m (30ST or higher) |
|
Mc: 4.37 N·m (10ST) 6.46 N·m (20ST) 8.84 N·m (30ST or higher) |
|
Operation life |
Horizontal 10 million operating cycles, vertical 5 million operating cycles |
Ambient operating temperature, humidity |
0 ~ 40°C, 85%RH or less (no condensation) |
Ingress protection |
IP20 |
Vibration & shock resistance |
4.9m/s2 |
Overseas standards |
CE marking, RoHS directive |
Motor type |
Stepper motor (φ20) |
Encoder type |
Incremental |
Number of encoder pulses |
32768 pulse/rev |
(Note 6) Based on the standard rated operation life of 5,000km. Operation life varies according to operating and mounting conditions. Please refer to General Catalog 2021 P. 1-244 for details on operation life.
■Table type moment direction
■Table of Payload by Speed/Acceleration
The unit for payload is kg.
Lead 4
Orientation |
Horizontal |
Vertical |
Speed (mm/s) |
Acceleration (G) |
|
0.5 |
0.5 |
|
0 |
1 |
0.4 |
100 |
1 |
0.4 |
150 |
1 |
0.4 |
200 |
1 |
0.4 |
Lead 2
Orientation |
Horizontal |
Vertical |
Speed (mm/s) |
Acceleration (G) |
|
0.3 |
0.3 |
|
0 |
2 |
0.8 |
20 |
2 |
0.8 |
50 |
2 |
0.8 |
100 |
2 |
0.8 |
■Stroke and Max. Speed
Lead (mm) |
10 (mm) |
20 (mm) |
30 (mm) |
40 (mm) |
50 (mm) |
4 |
200 <200> |
||||
2 |
100 <100> |
(Note) Values in brackets < > are for vertical use.
CONTINUE EDITING
■Dimensions by Stroke
5Cφ3 H7 reamed, depth 3
Stroke |
10 |
20 |
30 |
40 |
50 |
|
L(Note 8) |
Without brake |
93 |
103 |
113 |
123 |
133 |
With brake |
118 |
128 |
138 |
148 |
158 |
|
B |
27 |
37 |
47 |
57 |
67 |
|
C |
15 |
20 |
30 |
40 |
50 |
|
E |
4 |
4 |
4 |
4 |
4 |
|
N |
4 |
4 |
4 |
4 |
4 |
|
S |
40 |
60 |
80 |
90 |
100 |
|
T |
20 |
20 |
30 |
40 |
50 |
(Note 8) When selecting cable exit direction (option), 1 is subtracted from the dimensions.
■Mass by Stroke
Stroke |
10 |
20 |
30 |
40 |
50 |
|
Mass (kg) |
Without brake |
0.15 |
0.18 |
0.21 |
0.23 |
0.25 |
With brake |
0.17 |
0.20 |
0.23 |
0.25 |
0.27 |
■Applicable Controllers
21
(Note) EC Series products are equipped with a built-in controller. Please refer to P. 28 for details on built-in controllers.
EC-T3
ECELECYLINDER® EC-T3
22
ELECYLINDER SeriesOptions RCON-EC connection specification
Model ACR
Applicable modelsAll models
Description Brake
Select when connecting to a field network via an R-unit (connected to RCON-EC).
*This usage involves direct connection to RCON-EC. When using wireless communication, separately prepare an interface box, interface box conversion cable, and power / I/O cable connector.
Model B
Applicable modelsAll models
Description
This mechanism stops the slider, rod, or table from moving when the power or servo is turned off. When mounting the actuator vertically, this option is required.
Cable exit direction
ModelCJB/CJL/CJR/CJTApplicable modelsAll models
Description
The mounting direction of the actuator cable mounted on the actuator body can be changed among top, bottom, left, and right. Bottom: CJB Left: CJL Right: CJR Top: CJT
Non-motor end specification
Model NM
Applicable modelsAll models
Description
The home position is normally set to the motor side. This option is for setting the home position on the other side in order to accommodate variations in equipment layout, etc.
PN specification*Cannot be selected simultaneously with the ACR option
Model PN
Applicable modelsAll models
Description
For I/O specification, NPN is the standard specification. Specifying this option changes input/output to the PNP specification.
Split motor and controller power supply specification
* Cannot be selected with the ACR option (the RCON-EC connection specification is a split motor and controller power supply specification)
ModelTMD2
Applicable modelsAll models
Description
This option provides a separate motor power supply and control power supply. Select to allow shutting down the actuator drive power only. Please refer to P. 30 for more information on wiring.
Wireless communication specification*Cannot be selected simultaneously with the ACR option
Model WL
Applicable modelsAll models
Description
This option enables support for wireless communication. Specifying this option enables wireless communication with the TB-03 teaching pendant.The start point, end point, and AVD can be adjusted via wireless communication.
When using wireless communication with RCON-EC connection, separately prepare an interface box, conversion cable, and power / I/O cable connector.
Wireless axis operation support specification*Cannot be selected simultaneously with the ACR option
Model WL2
Applicable modelsAll models
Description
23
Specifying WL2 allows for the product to operate wirelessly as with WL (start point, end point, and AVD adjustment), and to also perform axis travel operation tests (forward end/backward end movement, jog, and inching). However, this function is not meant to perform automatic operation. Refer to P. 2-436 of the General Catalog 2021 for precautions on axis operations using a wireless connection.
(Note)Customers cannot change WL to WL2, or WL2 to WL. Please contact IAI for this.
When using wireless communication with RCON-EC connection, separately prepare an interface box, conversion cable, and power / I/O cable connector.
⬛Individual Options
Air cylinder mounting plates
These plates provide compatibility for mounting with some models of air cylinders. Plates can be mounted on the base side to enable mounting in accordance with the air cylinder body mounting hole positions.
Mounting to the table surface is not supported. Please contact our sales department for mounting compatibility details.
*Not shipped assembled. Assembly required.
⬛Applicable Model: EC-T3
⬛Model:EC-CSB-T3-(stroke)(Material: aluminum)
◆Accessories
- Hex socket bolts: M3×15 (4 pcs) · Parallel pins:φ3×8 B type h7 (2 pcs)
4
35
3+0.025 0
10 |
||
44 |
6.5
φ3H9+0.025
0Depth 2
6.5
3.3 φ |
M4 |
||||||||
φ6.5
Cross section of Y-Y
ZZ
Z |
||||||
(NN-1) x H |
G |
|||||
HB |
GB |
|||||
Y |
||||||
Y
NN-M4
X
Oblong hole depth 2
Detailed view of X
27 23 10
30 stroke speci cation
Stroke |
10 |
20 |
30 |
40 |
50 |
Z |
54.5 |
64.5 |
74.5 |
90.5 |
117.5 |
ZZ |
61 |
71 |
81 |
97 |
124 |
G |
15 |
22 |
* |
14 |
16 |
GB |
9 |
16 |
26 |
27 |
54 |
H |
25 |
28 |
* |
31 |
29 |
HB |
37 |
40 |
40 |
55 |
55 |
NN |
2 |
2 |
3 |
3 |
4 |
Mass [kg] |
0.062 |
0.074 |
0.086 |
0.104 |
0.136 |
*For 30 stroke, refer to the 30 stroke specification.
24
EC maintenance part model listSL3/GDS3/GDB3/T3
(2)
(1)
(1) Motor unit
(5)
(4)
(6)
The numbers in the table correspond to the numbers in the schematics.(1) Motor unit(Accessories: Bolts, screws, hex wrench)
(3)
(5)-1 Interface box
(2) Actuator cable mounting box (3) Actuator cable assembly (4) Interface box conversion cable (5) Interface box
(6) Stainless steel sheet
25
Type |
Brake |
Model |
SL3 GDS3 GDB3 T3 |
No |
EC-MUSLTGD3 |
Yes |
EC-MUSLTGD3-B |
(2) Actuator cable mounting box(Accessories: Screws)
Type |
Cable exit direction |
Model |
SL3 GDS3 GDB3 T3 |
Back |
EC-CASBR-SLTGD3 |
Side |
EC-CASBS-SLTGD3 |
(3) Actuator cable assembly(⬜⬜⬜is cable length)
Type |
Model |
SL3 GDS3 GDB3 T3 |
CB-EC-SLTGD3-MPA⬜⬜⬜-AS |
(4) Interface box conversion cable
Type |
Model |
SL3 GDS3 GDB3 T3 |
CB-CVN-BJ002 |
Type |
Wireless |
I/O |
Model |
SL3 GDS3 GDB3 T3 |
None |
NPN |
ECW-CVN-CB |
PNP |
ECW-CVP-CB |
||
WL WL2 |
NPN |
ECW-CVNWL-CB |
|
PNP |
ECW-CVPWL-CB |
(5)-2 Split motor and controller power supply interface box
Type |
Wireless |
I/O |
Model |
SL3 GDS3 GDB3 T3 |
None |
NPN |
ECW-CVN-CB-TMD2 |
PNP |
ECW-CVP-CB-TMD2 |
||
WL WL2 |
NPN |
ECW-CVNWL-CB-TMD2 |
|
PNP |
ECW-CVPWL-CB-TMD2 |
(5)-3 RCON-EC connection specifi cation (option model: ACR) split motor and controller power supply interface box
Type |
Wireless |
I/O |
Model |
SL3 GDS3 GDB3 T3 |
WL WL2 |
NPN _REC |
ECW-CVNWL-CB-ACR |
(6) Stainless steel sheet
Type |
Model |
SL3 |
ST-EC-SL3-(stroke) |
Push-motion operation
Push-motion operation is a function that keeps the rod or table pushed up against the workpiece, as with an air cylinder.
Please check the usage instructions and precautions below prior to use.
[Precautions]
-
When pushing, the static and dynamic allowable moments of the guide must be taken into consideration.
[Push force adjustment]
- The push force during push-motion operation can be adjusted by changing the "push force (%)" on ELECYLINDER.
- Please check the push force for the applicable model in the "Correlation
(Example)22
EC-T3
⬛Recommended area
20
Diagrams between Push Force and Current Limit" on the production
18
specification page, and select a model that matches your conditions.Push force (N)
16
14
12
10
8
[Lead selection method]
6
4
Select a lead with the desired push force within the recommended current 2
Lead 2 (upper limit value) |
||||||||||
Lead 2 (average value) |
||||||||||
Lead 2 (lower limit value) |
||||||||||
Lead 4 (upper limit value) |
||||||||||
Lead 4(average value) |
||||||||||
Lead 4 (lower limit value) |
limit value range (yellow area of the graph).
Lead 4 would be appropriate for the EC-T3 type shown in the figure to the right if a push force of 8N is desired. Selecting lead 2 would limit the adjustment range.
Caution
403020100 50 60 70 80 90 100 1100Current limit value (%)
<Correlation Diagrams between Push Force and Current Limit>
- The "Correlation Diagrams between Push Force and Current Limit" show lower guidelines for push force for each current limit value.
- Individual differences in the motor and variations in machine efficiency may cause the push force lower limit to be exceeded, even if the current limit value is the same.
This is especially true when the current limit value is 30% or lower, in which case the push force lower limit could be exceeded by 40% or more.
Overhang load length (ℓ)
This is the approximate offset at which the actuator can operate smoothly even when the workpiece or bracket is offset from the slider. Vibration or other factors could cause failure if the approximate length is greatly exceeded. The product should therefore be used within the approximate length. Please refer to the reference page of each model for detailed figures.
ℓ
ℓ
26
Selection notes
When connecting the Ultra-Mini ELECYLINDER to a PLC, three connection methods are available. Select from these three connection methods.
Take note of the connection restrictions and items to be prepared separately. *Contact our sales department to change the connection method after purchase.
-
When connecting directly to the PLC (NPN/PNP specifications)
Actuator cable (Note)(Cable length selection: 1m ~ 9m)
Interface box conversion cable<CB-CVN-BJ002>
Interface box
Power / I/O cable connector
or
terminal block connector (Note)
(Cable length selection: 0m ~ 9m)
PLC
Ultra-Mini ELECYLINDER
Standard accessories * Interface box specifi cations diff er according to the options selected.
(Note) The total cable length of the actuator cable and power / I/O cable connector (cable prepared by the customer in the case of the terminal block connector) should be selected so as not to exceed 10m.
- When connecting to the PLC via an EC connection unit (RCON-EC connection specification) [Teaching pendant connected via wiring]
Actuator cable
(Cable length selection: 1m ~ 10m)
Ultra-Mini ELECYLINDER
*Option: Select ACR
EC connection unit
Prepared by customer
Teaching pendant TB-03 (wired)
PLC
- When connecting to the PLC via an EC connection unit (RCON-EC connection specification) [Teaching pendant wirelessly connected]
RCON-EC connection
Actuator cable (Note)(Cable length selection: 1m ~ 9m)
Interface
box
<ECW-CVNWL-CB-ACR>
Interface box
conversion cable
<CB-CVN-BJ002>
specifi cation
power / I/O cable
connector (Note)
(Cable length selection: 1m ~ 9m)
Prepared by
customer
PLC
Ultra-Mini ELECYLINDER
*Option: Select ACR
27
Prepare separately
EC connection unit
Teaching pendant TB-03 (wireless)
(Note) Select so that the total length of the actuator cable and RCON-EC connection specification power / I/O cable connector is 10m or less.
System Configuration PLC
<Wires>
Select AWG18 or higher
for 24V and 0V and AWG26 or higher for others.
* All cables should be 10m or shorter.
Accessory
Power / I/O connector
Connector for connecting
customer-side power wiring. <Model: 1-1871940-6>
Accessory
Accessory
Interface
box
(See P. 32)
* Specifi cations included
diff er according to
actuator option selection.
Options
PC
teaching software(See P. 32)
Software only
<Model: IA-OS>
Dedicated connection cable included
<Model: IA-OS-C>
Accessory
Interface
Accessories: Included when designated in actuator model number Options: Separate order required
Options
EC connection unit
(Refer to page 2-405 of the
General Catalog 2021)
< Model: REC-GW-⬜
+RCON-EC-4>
Unit to connect to the fi eld
network.
(Note) Wiring to the EC connection unit diff ers between wired and wireless connection.
See "EC connection unit wiring" for the wiring.
Power / I/O cable
(See P. 33)
<Model: CB-EC-PWBIO⬜⬜⬜-RB (standard connector)>
<Model: CB-EC2-PWBIO⬜⬜⬜-RB (4-way connector)>
Cable for connecting power and PLC I/O signals.
Options
box conversion cable
(See P. 32)
<Model: CB-CVN-BJ002>
Options
Options
24VDC power supply
(See P. 32)
<Model: PSA-24>
EC connection unit wiring
(For teaching pendant wired connection)
Wireless/wired touch
panel teaching
pendant with power
supply unit
(See P. 32)
<Model: TB-03E-SCN-⬜>
* Can also connect to wired-only
touch panel teaching pendant
with power supply unit "TB-02E."
(For teaching pendant wireless connection)
Options
Power / I/O cable
(See P. 33)
Wireless/wired
touch panel
teaching pendant(See P. 32)
<Model: TB-03-⬜>
* Can also connect to wired-only touch panel
teaching pendant
"TB-02."
Options
EC connection unit
Options
<Model: CB-REC-PWBIO⬜⬜⬜-RB (standard connector)><Model: CB-REC2-PWBIO⬜⬜⬜-RB (4-way connector)>
Options
EC connection unitOptions
OptionsTouch panel
List of Accessories
⬛Power / I/O Cables, Connectors [Standard connector]
Touch panel
teaching pendant (wired connection)
Interface
box conversion cable(See P. 32)
<Model: CB-CVN-BJ002>
teaching pendant (wireless connection)
Product category
Power I/O cable connector length Accessory
(selected with actuator model)
RCON-EC connection specifi cation (ACR) selection |
None |
Yes |
None |
0Power / I/O connector (1-1871940-6) —
1 to 9 Power / I/O cable (CB-EC-PWBIO⬜⬜⬜-RB)[Four-way connector]
Product category
Power I/O cable connector length Accessory
(selected with actuator model)
RCON-EC connection specifi cation (ACR) selection |
None |
28
S1 ~ S9 Power / I/O cable (CB-EC2-PWBIO⬜⬜⬜-RB)
Basic Controller Specifications
Specification item Specification content Number of controlled axes 1 axis
Power supply voltage 24VDC ±10%
Power capacity (Note 1) Rated 0.7A, max. 1.1A
Brake release power supply 24VDC ±10%, 200mA (only for external brake release) Generated heat 2W
Inrush current (Note 2) 3A
Momentary power failure resistance Max 500µs
Motor sizeφ20
Motor rated current 0.4A
Motor control system Weak field-magnet vector control
Supported encoders Incremental (32768 pulse/rev)
SIO RS-485 1ch (Modbus protocol compliant)
Interface
box
specification
Input specification |
No. of inputs |
Input voltage |
|
Input current |
|
Leakage current |
|
Isolation method |
|
Output specification |
No. of outputs |
Output voltage |
|
Output current |
|
Residual voltage |
|
Isolation method |
3 points (forward, backward, alarm clear)
24VDC ±10%
5mA per circuit
Max. 1mA/1 point
Non-isolated
3 points (forward complete, backward complete, alarm) 24VDC ±10%
50mA/1 point
2V or less
Non-isolated
Data setting, input method PC teaching software, touch panel teaching pendant
Data retention memory Position and parameters are saved in non-volatile memory (no limit to number of rewrites)
LED
display
Controller status display |
Wireless status display |
Forward end/backward end display (Note 3) |
Servo ON (green light ON) / Alarm (red light ON) / Initializing when power comes ON (orange light ON) / Minor failure alarm (green/red alternately blinking) / Operation from teaching: Stop from teaching (red light ON) / Servo OFF (light OFF)
Initializing wireless hardware, without wireless connection, or connecting from TP board (light OFF) Connecting through wireless (green blinking) / Wireless hardware error (red blinking) / Initializing when power comes ON (orange light ON)
Lit orange: Forward end/backward end, push idling detection
Blinking orange: Push complete
Predictive maintenance/preventative maintenance
When the number of movements or operation distance has exceeded the set value and when the LED (right side) blinks alternately green and red at overload warning
*Only when configured in advance
Ambient operating temperature 0 ~ 40°C
Ambient operating humidity 5%RH ~ 85%RH or less (no condensation or freezing)
Operating ambience No corrosive gas or excessive dust
Insulation resistance 500VDC 10MΩ
Electric shock protection mechanism Class 1 basic insulation
Cooling method Natural air cooling
(Note 1) When connecting to RCON-EC, 0.3A is subtracted from the value.
(Note 2) Inrush current flows for approximately 5ms after the power is input. (At 40°C) Inrush current value differs depending on the impedance on the power line. (Note 3) The LED display function can be changed via parameter setting.
Solenoid Valve Method
ELECYLINDER products normally use a double solenoid method.
Change parameter No. 9 ("solenoid valve type selection") to use the single solenoid method.
<Caution>
Operation cannot be performed using the single solenoid method when operating connected to RCON-EC.
29
Interface Box Specification (I/O specification)
I/O |
Input |
||
Input voltage |
24VDC ±10% |
Load voltage |
|
Input current |
5mA per circuit |
Maximum load current |
|
Specifications |
ON/OFF voltage |
ON voltage: MIN. 18VDC OFF voltage: MAX. 6VDC |
Residual voltage |
Leakage current |
Max. 1mA/1 point |
Leakage current |
|
solation method |
Non-isolated from external circuit |
||
NPN |
Internal power24V Internal circuit Input terminal 16 |
Internal circuit |
|
PNP |
External power 24V Internal circuitInput terminal 16 |
Internal power 24V Internal circuit |
Output
24VDC ±10%
50mA/1 point
2V or less
Max. 0.1mA/1 point
INon-isolated from external circuit
External power 24V
Load
Output terminal
I/O
logic
Load
Output terminal
(Note) Isolation method is non-isolated. When grounding an external device (such as a PLC) connected to ELECYLINDER, use the same ground as ELECYLINDER.I/O Signal Wiring Diagram
I/O |
Standard specification |
Split motor and controller power supply specification (option model: TMD2) |
Power / I/O connector |
0V A1 B1 24V (Reserved) A2 B2 Brake release Backward complete A3 B3 Backward command (Note 1) Forward complete A4 B4 Forward command (Note 1) B5 Alarm clear Alarm output A5 B6 (reserved) (Reserved) A6 |
Drive power and control power are separate for the TMD2 specifi cation. 0V A1 B1 24V (drive) 24V (control)A2 B2 Brake release Backward complete A3 B3 Backward command (Note 1) Forward complete A4 B4 Forward command (Note 1) B5 Alarm clear Alarm output A5 B6 (reserved) (Reserved) A6 |
NPN |
0V 24V 0V 24V A1 B1 Brake release B2 Backward complete A3 B3 (Note 1) Backward command Forward complete A4 B4 (Note 1) Forward command Alarm output Alarm clear A5 B5 |
0V 24V A1 0V 24V (drive) B1 Brake release B2 A2 24V (control) B3 A3 Backward complete (Note 1) Backward command B4 A4 Forward complete (Note 1) Forward command B5 A5 Alarm output Alarm clear |
PNP |
24V 0V 24V 0V B1 A1 Brake release B2 B3 Backward complete A3 (Note 1) Backward command B4 Forward complete A4 (Note 1) Forward command Alarm clear B5 Alarm output A5 |
24V 0V A1 B1 24V (drive) 0V B2 Brake release A2 24V (control) B3 A3 Backward complete (Note 1) Backward command B4 A4 Forward complete (Note 1) Forward command A5 B5 Alarm output Alarm clear |
I/O
logic
(Note 1) Switching to the single solenoid method will change B3 to "forward/backward command" and B4 to "unused."
30
I/O Signal Table
Power / I/O connector pin assignment
Connector nameplate name |
Signal abbreviation |
Backward |
ST0 |
Forward |
ST1 |
Alarm clear |
RES |
Backward complete |
LS0/PE0 |
Forward complete |
LS1/PE1 |
Alarm |
*ALM |
Brake release |
BKRLS |
24V |
24V |
0V |
0V |
(24V) |
(24V) |
Pin No. Function overview B3 (Note 1) Backward command B4 (Note 1) Forward command B5 Alarm clear A3 Backward complete/push complete A4 Forward complete/push complete A5 Alarm detection (b-contact) B2Brake forced release (for brake equipped specification)B1 (Note 2) 24V input A1 0V input A2 (Note 2) 24V input
(Note 1) Switching to the single solenoid method will change B3 to "forward/backward" and B4 to "unused." However, the power / I/O connector display will still read "B3: Backward" and "B4: Forward."
(Note 2) B1 is 24V (drive) and A2 is 24V (control) for the split motor and controller power supply specification (TMD2).
Options
Wireless/wired touch panel teaching pendant
⬛TB-03 Body Specifications
⬛FeaturesThis teaching device supports wireless connections. Start point/end point/AVD input and axis operation
Power input voltage range
24VDC ±10% [supplied from controller] 5.9VDC (5.7 ~ 6.3V) [supplied from AC adapter]
can be performed wirelessly.
⬛ModelTB-03-⬜Please contact IAI for the current supported versions. ⬛ConfigurationWireless or wired connection
Power consumption3.6W or less
Consumption current150mA (supplied from controller)Ambient operating temperature0 ~ 40°C (no condensation or freezing)Ambient operating humidity5%RH ~ 85%RH (no condensation or freezing)Ambient storage temperature-20 ~ 40°C
Vibration resistance10 ~ 57Hz / Amplitude: 0.075mmIngress protectionIPX0
Mass 670g (body) + approx. 285g (dedicated cable) Liquid crystal 7" TFT color WVGA (800 x 480)
5m
External memory
SD/SDHC memory card interface mounted (1GB ~ 32GB)
Wired/wireless touch panel teaching pendant with power supply unit
⬛ModelTB-03E-⬜Please contact IAI for the current supported versions. ⬛ConfigurationWireless or wired connection
Charging methodWired connection with dedicated AC adapter/controllerLanguage supportJapanese/English/Chinese
⬛Power Supply Unit Specifications
Rated input voltage Single-phase 100 ~ 230VAC±10% Input current1.4A typ. (100VAC)
Under rated I/O conditions
in ambient temperature of 25°C
0.6A typ. (230VAC)
Frequency range 50/60Hz ±5%Power capacity141VA (100VAC)
Under rated I/O conditions
See General Catalog 2021 P. 2--437
in ambient temperature of 25°C
145VA (230VAC)
Output voltage 24VDC ±10%
5m
Load
current
Standard Dust-proof/splash-proof High rigidity |
Mini type |
With energy-saving setting disabled: Rated 3.5A, max. 4.2A
With energy-saving setting enabled: Rated 2.2A Max. 2.0A
Output capacityWith energy-saving setting disabled: Rated 84W, max. 98.4W With energy-saving setting enabled: Rated 52.8W
Ambient operating temperature0 ~ 40°C (no condensation or freezing)Ambient operating humidity5%RH ~ 85%RH (no condensation or freezing)Ambient storage temperature-20 ~ 70°C
Atmosphere No corrosive gas or excessive dust Altitude 1000m or less above sea level
Frequency: 10 ~ 57Hz / Amplitude: 0.075mm
Vibration resistance
Frequency: 57 ~ 150Hz / Acceleration: 9.8m/s2
[XYZ directions] Sweep time: 10 minutes, Number of sweeps: 10
31
Package dropDrop height: 800mm / 1 corner, 3 edges, 6 facesOvervoltage category II
Pollution degree 2
Electric shock protection classII
Ingress protection IP30
Mass Approx. 740kg
Cooling method Natural air cooling
PC teaching software (Windows only)
⬛FeaturesThis start-up support software provides functions such as position teaching, trial operation, and monitoring. It provides a complete range of functions required to make adjustments, to help reduce start-up time.
Supported Windows versions: 7/10
⬛Model
IA-OS(software only, for customers who already own a dedicated connection cable)* Please purchase through your distributor and a download link will be sent to your valid email address.
Please contact IAI for the current supported versions.
⬛Con guration
PC software (CD) (Download only)
Your dedicated cableCB-SEL-USB030/RCB-CV-USB/ CB-RCA-SIO050
⬛Model
IA-OS-C(with an external device communication cable + USB conversion adapter + USB cable)* Please purchase through your distributor and a download link will be sent to your valid email address.
Please contact IAI for the current supported versions.
⬛Con guration
USB conversion adapter
RCB-CV-USB
3m 5m
PC software (CD) (Download only)
24V power
USB cable
CB-SEL-USB030
External device communication cable CB-RCA-SIO050
⬛ModelPSA-24(without fan)⬛Speci cations Table
ItemSpecifi cations200VAC input
⬛Model
PSA-24L(with fan)
100VAC input |
Power input voltage range100VAC ~ 230 VAC ±10%
3.9A or less |
Without fan: 250VA With fan: 390VA |
Without fan: 17A (typ) With fan: 27.4A (typ) |
23W (204W continuous rated) 37W (300W continuous rated) |
Input power supply current1.9A or less
⬛External Dimensions
PSA-24
39.6
16.4
4
22
115 |
Power capacityWithout fan: 280VA
With fan: 380VA
Inrush current *1Without fan: 34A (typ)
Φ5
With fan: 54.8A (typ)
Generated heat33W (204W continuous rated)
5
54W (330W continuous rated)
Output voltage range *224V ±10%
105
35.2
Continuous rated output
Without fan: 8.5A (204W) With fan: 13.8A (330W)
140
142.8 |
3.5
54
55
22
Peak output 17A (408W)
86% or more |
Effi ciency 90% or more
PSA-24L
16.4
55.6 |
35.24
140
54
131 |
3.5
522
Φ |
||||
1) |
||||
(2 |
||||
5 105 |
||||
22 |
5 |
5 |
Parallel connection *3Up to 5 units
*1 The pulse width of flowing inrush current is less than 5ms.
*2 This power supply can vary the output voltage according to the load in order to enable parallel operation. The power supply unit is therefore for use with IAI controllers only. *3 Parallel connection cannot be used under the following conditions.
⬤Parallel connection of PSA-24 (specification without fan) and PSA-24L (specification with fan)⬤Parallel connection with a power supply unit other than this power supply⬤Parallel connection with PS-24
142.8 |
Power capacity calculation “Calculator” software
Just input the model number of the ELECYLINDER to be connected to ensure su cient units for 24V power.
IAI Calculator |
RCON-EC connection speci cation
split motor and controller power supply interface box (wireless)
⬛ModelECW-CVNWL-CB-ACR
Interface box conversion cable
⬛FeaturesThis cable connects the actuator cable and interface box.
⬛ModelCB-CVN-BJ002
40
Actuator side
Interface
box side
32
Maintenance/Optional Parts (cables)
When individually ordered cables or replacements must be ordered, refer to the model number below.
⬛Table of Compatible Cables
Cable type |
Cable model |
Power / I/O cable (user-wired specification) |
CB-EC-PWBIO⬜⬜⬜-RB |
Power / I/O cable (user-wired specification, four-way connector) |
CB-EC2-PWBIO⬜⬜⬜-RB |
Power / I/O cable (RCON-EC connection specification) |
CB-REC-PWBIO⬜⬜⬜-RB |
Power / I/O cable (RCON-EC connection specification, four-way connector) |
CB-REC2-PWBIO⬜⬜⬜-RB |
ModelCB-EC-PWBIO⬜⬜⬜-RB*Please indicate the cable length (L) in⬜⬜⬜, maximum 9m (for example, 030 = 3m)
3-1871946-6
(18)
(49.1)
Color |
Signal name |
Pin No. |
Black (AWG18) |
0V |
A1 |
Red (AWG18) |
24V |
B1 |
Light blue (AWG22) |
(Reserved) (Note 1) |
A2 |
Orange (AWG26) |
IN0 |
B3 |
Yellow (AWG26) |
IN1 |
B4 |
Green (AWG26) |
IN2 |
B5 |
Pink (AWG26) |
(Reserved) |
B6 |
Blue (AWG26) |
OUT0 |
A3 |
Purple (AWG26)Gray (AWG26) |
OUT1 OUT2 |
A4 A5 |
White (AWG26) |
(Reserved) |
A6 |
Brown (AWG26) |
BKRLS |
B2 |
(φ7.2)
L 500
(34.2)
Actuator side
Minimum bending R: r = 58mm or more (for movable use) *Only the robot cable is available for this model.
(Note 1) 24V (control) when split motor and controller power supply specification (TMD2) is selected.
ModelCB-EC2-PWBIO⬜⬜⬜-RB*Please indicate the cable length (L) in⬜⬜⬜, maximum 9m (for example, 030 = 3m)
L500
(34.2)
(18) (39.3)
(φ7.2)
Minimum bending R: r = 58mm or more (for movable use)*Robot cable is standard.
Actuator side
Cap for L-shaped cover
Connector assembly diagram
3-1871946-6
Color Black (AWG18) |
Signal name 0V |
Pin No. A1 |
Red (AWG18) |
24V |
B1 A2 |
Light blue (AWG22)Orange (AWG26) |
(Reserved) (Note 1)IN0 |
B3 |
Yellow (AWG26) |
IN1 |
B4 |
Green (AWG26)Pink (AWG26) |
IN2 (Reserved) |
B5 B6 |
Blue (AWG26) |
OUT0 |
A3 |
Purple (AWG26) |
OUT1 |
A4 |
Gray (AWG26) |
OUT2 |
A5 |
White (AWG26)Brown (AWG26) |
(Reserved) BKRLS |
A6 B2 |
(32.3)
(Note 1) 24V (control) when split motor and controller power
supply specification (TMD2) is selected.
ModelCB-REC-PWBIO⬜⬜⬜-RB*Please indicate the cable length (L) in⬜⬜⬜, maximum 9m (for example, 030 = 3m)
3-1871946-6 DF62C-13S-2.2C(18)
(18)
(34.2)
(49.1)
L
(φ7.2)(30)(11.5)(11.5)
ColorSignal namePin No. Black (AWG18) 0V A1 Red (AWG18) 24V (MP) B1 Light blue (AWG22)24V (CP) A2 Orange (AWG26) IN0 B3 Yellow (AWG26) IN1 B4 Green (AWG26) IN2 B5 Yellow (AWG26) SD+ B6 Light gray (AWG26)SD- A6
Pin No.Signal nameColor 2 0V Black (AWG18) 1 24V (MP) Red (AWG18)
12 24V (CP)Light blue (AWG22) 7 OUT0 Orange (AWG26) 8 OUT1 Yellow (AWG26) 9 OUT2 Green (AWG26) 6 SD+ Yellow (AWG26) 10 SD-Light gray (AWG26)
Minimum bending R: r = 58mm or more (for movable use)*Only the robot cable is available for this model.
Actuator side
R-unit side
Blue (AWG26) OUT0 A3 Purple (AWG26) OUT1 A4 Gray (AWG26) OUT2 A5 Brown (AWG26) BKRLS B2
3 INO Blue (AWG26) 4 IN1 Purple (AWG26) 5 IN2 Gray (AWG26) 11 BKRLS Brown (AWG26) 13 FG Green (AWG26)
ModelCB-REC2-PWBIO⬜⬜⬜-RB*Please indicate the cable length (L) in⬜⬜⬜, maximum 9m (for example, 030 = 3m)
(18) (39.3)L
(30)
(φ7.2)(11.5)
(34.2)
(11.5)
Actuator side
Minimum bending R: r = 58mm or more (for movable use)*Robot cable is standard.Connector assembly diagram
R-unit side
1-1871946-6 DF62C-13S-2C(18)
33
Cap for L-shaped cover
(32.3)
ColorSignal namePin No. Black (AWG18) 0V A1 Red (AWG18) 24V (MP) B1 Light blue (AWG22)24V (CP) A2 Orange (AWG26) IN0 B3 Yellow (AWG26) IN1 B4 Green (AWG26) IN2 B5 Yellow (AWG26) SD+ B6 Light gray (AWG26)SD- A6 Blue (AWG26) OUT0 A3 Purple (AWG26) OUT1 A4 Gray (AWG26) OUT2 A5 Brown (AWG26) BKRLS B2
Pin No.Signal nameColor 2 0V Black (AWG22) 1 24V (MP) Red (AWG22)
12 24V (CP)Light blue (AWG22) 7 OUT0 Orange (AWG26) 8 OUT1 Yellow (AWG26) 9 OUT2 Green (AWG26) 6 SD+ Yellow (AWG26) 10 SD-Light gray (AWG26) 3 INO Blue (AWG26) 4 IN1 Purple (AWG26) 5 IN2 Gray (AWG26) 11 BKRLS Brown (AWG26) 13 FG Green (AWG26)