2-DAY $10 SHIPPING OR FREE SHIPPING OVER $250 **shipping policy

Search
•Real time inventory
•Fast and reliable shipping
•Orders before 3pm(PST) ship same day

Noark | Mini Circuit Breaker, 2P, D-Curve, 7A, UL489, 240VAC/125VDC, 10 kA, Box Lug | B1N2D7


Mfr. Part #: B1N2D7

4 in stock | Need More? >>


Ships same day with standard 2-day shipping if ordered M-F before 3PM PT.

Pickup Available at Livermore

MCB UL489 - 1002127 - 2P - 7A - D-curve - 10kA - 240Vac/125Vdc

Miniature Circuit Breaker (MCB) - UL489 - NOARK (B1N series) - 7A rated current - D-curve - 2-poles (2P) - 10kA (240Vac) / 10kA (125Vdc) interrupting rating - 240Vac / 125Vdc rated voltage - box lug connections - DIN rail mounting (35mm width) - equivalent to 1002127

Specification Details
Primary Brand NOARK
Main Function Miniature Circuit Breaker (MCB)
Product Series / Family Name Electrical protection > Circuit breakers > Miniature Circuit Breakers (MCBs) > UL489 > for AC applications
Sub-range Name B1N series
Network Frequency 50/60 Hz
Functions Miniature Circuit Breaker (MCB)
Design Thermal-Magnetic inverse time-delay over-current release type
Tripping Curve "D" Tripping curve (thermal overload trip occurs at currents ranging from 10 to 20 x the nominal current)
Poles 2-poles (2P)
Rated Current 7A
Rated Voltage (DC) 125Vdc
Rated Voltage (AC) 240Vac
Rated Impulse Voltage (Uimp) 6 kV
Rated Insulation Voltage (Ui) 500 V
Connection Type Box lug connections
Cross-section For #18AWG...#4AWG / 0.75mm²...25mm² conductors (when using a single conductor per lug)
For #18AWG...#6AWG / 0.75mm²...16mm² conductors (when using 2 conductors per lug)
Short Circuit Breaking Rating 10kA (240Vac)
10kA (60Vdc)
10kA (125Vdc)
Protection Functions Overvoltage III
Mounting Mode DIN rail
Degree of Protection IP20
Dimensions H109.3mm x W35.6mm x D79mm
H4.3" x W1.4" x D3.11"
Net Width (mm) 35 mm
Ambient Air Temperature for Operation -22°F...+167°F / -30°C...+75°C
Climatic Resistance At +68°F (+20°C) the relative humidity does not exceed 90%
At +104°F (+40°C) the relative humidity does not exceed 50%
Altitude does not exceed 6561ft (2000m)
Electrical Durability (with load) 10000 operations
Mechanical Durability (at no load) 20000 operations
Order Code / Manufacturer SKUB1N2D7
1002127
Manufacturer Product Status Commercialized
Equivalent to 1002127
Compliant with Standard(s) UL489
CSA C22.2 No.5-16
UL489 (file number E355392)
UL486
IEC60947-2
RoHS compliant
Benefits - Breakers mount on standard 35mm DIN rail
- Can be used in UL 1077 or CSA C22.2 No.235 applications
- Field installable shunt trip and auxiliary switch
- Available with provisions for ring tongue terminals
- Module width of only 0.71 in (18 mm) per pole
- Contact position indicator (red/green)
- Possibility for locking the toggle in ON or OFF position
Degree of Pollution 3
Application Type - Branch Circuit Protection
- Convenience receptacle circuits (internal/external)
- Motor control circuits
- Load circuits leaving the equipment (external)
- HVACR equipment -- heating / ventilation / air conditioning / refrigeration (internal/external)
- PLC I/O points
- Power supplies
- Control instrumentation
- Relays
- UPS
- Power conditioners

ID #: 186906