iDP Valves
101 Series
10mm, 2-Port Manifold iDP Valve
Introduction
The iDP 101 Series Valve is a miniature, diaphragm-separated, 2-port valve designed for precise control and reliable performance in micro-dosing applications. At just 10 millimeters in width, this valve is ideal for controlling aggressive media, including fluids and chemical reagents, used in medical technology and analytical fields. Applications range from microfluidics to DNA analysis and various biological sampling (blood, urine, and tissue). Its simple design ensures long-lasting, trouble-free operation for millions of cycles.
Features
-
Inert Wetted Materials for broad compatibility:
- Radel® body
- FKM or EPDM elastomers
-
Low Internal Volume:
- 30 μL actuated
- 3.6 μL unactuated (under seat)
- Fluid Pressure: Up to 30 PSI [2.06 bar]
-
Flow Rates:
- 550 mL/min [water]
- 20 SLPM [air]
- Compact Subbase Mount for easy system integration.
- Tight Footprint: Allows for multiple valves in a small space.
- Electrical Entry: 12 or 24VDC lead wire plug-in electrical entry.
- Ideal for Micro-Dosing engineered solutions.
Here is the specification table for the iDP 300 Series in both Inline and Manifold configurations:
SPECIFICATIONS
Specification | IDP 300 Inline | IDP 300 Manifold |
---|---|---|
Type of Operation | Direct Solenoid, Media Separated | Direct Solenoid, Media Separated |
Number of Positions | 2 | 2 |
Function | Normally Closed | Normally Closed |
Media | Aggressive Liquids and Gases | Aggressive Liquids and Gases |
Wetted Parts (Body & Diaphragm-Poppet) | PEEK, Viton®GF or EPDM | PEEK, Viton®GF or EPDM |
Pressure Range | Vacuum to 40 PSI (2.76 bar) | Vacuum to 40 PSI (2.76 bar) |
Piping Type | Inline, Direct Piping | Manifold Mount, Sub-base Piping |
Water Flow @ 40 PSI (TYP) | 1.45 SLPM | 1.83 SLPM |
Air Flow @ 40 PSI (TYP) | 50 SLPM | 62 SLPM |
Fluid Temperature | -20°C to 95°C | -20°C to 95°C |
Ambient Temperature | -20°C to 65°C | -20°C to 65°C |
Cycles/Min | 300 | 300 |
Response Time @ 40 PSI (TYP) | 25 msec | 25 msec |
Port Size | 1/16”, 3/32” or 1/8” | -- |
Electrical Entry | Plug-In or Lead Wires | Plug-In or Lead Wires |
Voltages | 12VDC, 24VDC | 12VDC, 24VDC |
Voltage Tolerance | ±10% | ±10% |
Power Consumption (Watts) | 3.5 | 3.5 |
Weight | 0.22 lbs | 0.27 lbs |
300 SERIES 2-WAY INTERNAL VOLUMES
Body Size | Unactuated Under Poppet | Actuated |
---|---|---|
1/16” Barb Body | 0.007 in³ | 0.013 in³ |
3/32” Barb Body | 0.007 in³ | 0.014 in³ |
1/8” Barb Body | 0.009 in³ | 0.017 in³ |
Manifold | 0.004 in³ | 0.012 in³ |
Media Compatibility
- Concentrated Nitric Acid
- Sodium Hydroxide
- Ethylene Diamine
- Ethylene Glycol
- Renaline®
- Formaldehyde
- Biological Solutions
- Sodium Hypochlorite
- Dialysate
- Hydrogen Peroxide
- Bleach/Lye
Applications & Markets
The iDP 101 Series Valve is designed for precise control in a wide variety of applications, including:
- Microfluidics
- DNA analysis
- Blood, Urine, and Tissue Sampling
- Medical Technology
- Analytical Systems
- Chemical Processing
This valve is particularly well-suited for applications in the healthcare, biotechnology, and laboratory industries, where precise media control and reliability are critical.
iDP Valves
300 Series, 2-Port
Inert Diaphragm-Poppet Valve
Introduction
Humphrey’s 300 Series iDP 2-way inline and manifold valves are designed for precise control of aggressive media in harsh environments. Featuring a compact design, the 300 series offers a flexing diaphragm-poppet that isolates the solenoid from the media, ensuring long-term performance and reliability. Ideal for applications where space is limited, this valve provides robust performance, making it suitable for demanding chemical and industrial applications.
Features
-
Inert Wetted Materials for broad chemical compatibility:
- Body/Fitting Elements: PEEK (Polyetheretherketone)
- Diaphragm-Poppet/Seals: Viton®-GF or EPDM
- Max Pressure: 40 PSI [2.76 bar] standard
-
Flow Rates:
-
Barb Valve @ 40 PSI:
- 50 SLPM air
- 1.45 SLPM water
-
Manifold Valve @ 40 PSI:
- 62 SLPM air
- 1.83 SLPM water
-
Barb Valve @ 40 PSI:
- Coil Encapsulation: Protects the valve from corrosive external fluid exposure.
- Port Types and Mounting Options: Offers design flexibility with various configurations.
- Tested Durability: Capable of withstanding more than 20 million cycles.
- Available in 3-Port Inline Barb Valve Option.
Specification | IDP 300 Inline | IDP 300 Manifold |
---|---|---|
Type of Operation | Direct Solenoid, Media Separated | Direct Solenoid, Media Separated |
Number of Positions | 2 | 2 |
Function | Normally Closed | Normally Closed |
Media | Aggressive Liquids and Gases | Aggressive Liquids and Gases |
Wetted Parts | PEEK, Viton®GF or EPDM | PEEK, Viton®GF or EPDM |
Pressure Range | Vacuum to 40 PSI (2.76 bar) | Vacuum to 40 PSI (2.76 bar) |
Piping Type | Inline, Direct Piping | Manifold Mount, Sub-base Piping |
Water Flow @ 40 PSI (TYP) | 1.45 SLPM | 1.83 SLPM |
Air Flow @ 40 PSI (TYP) | 50 SLPM | 62 SLPM |
Fluid Temperature | -20°C to 95°C | -20°C to 95°C |
Ambient Temperature | -20°C to 65°C | -20°C to 65°C |
Cycles/Min | 300 | 300 |
Response Time @ 40 PSI | 25 msec | 25 msec |
Port Size | 1/16”, 3/32” or 1/8” | -- |
Electrical Entry | Plug-In or Lead Wires | Plug-In or Lead Wires |
Voltages | 12VDC, 24VDC | 12VDC, 24VDC |
Voltage Tolerance | ±10% | ±10% |
Power Consumption | 3.5 Watts | 3.5 Watts |
Weight | 0.22 lbs | 0.27 lbs |
Internal Volumes
-
Unactuated Under Poppet:
- 1/16” Barb Body: 0.007 in³
- 3/32” Barb Body: 0.007 in³
- 1/8” Barb Body: 0.009 in³
- Manifold: 0.004 in³
-
Actuated:
- 1/16” Barb Body: 0.013 in³
- 3/32” Barb Body: 0.014 in³
- 1/8” Barb Body: 0.017 in³
- Manifold: 0.012 in³
Media Compatibility
- Citric Acid
- Formaldehyde
- Biological Solutions
- Sodium Hypochlorite
- Dextrose/Sugars
- Dialysate
- Hydrogen Peroxide
- Acetic Acid
- Bleach/Lye
- Most aggressive medias
Applications & Markets
The iDP 300 Series valve is designed for a range of applications including:
- Kidney Dialysis
- Analytical Chemistry
- Diagnostic Systems
- Agent Detection
- Environmental Monitoring
- Food and Beverage Processing
- Gaseous Flow Control
- Water Purification
- Clinical Diagnostics
This valve offers an ideal solution for applications that require precise control in harsh environments, especially in the medical, chemical, and industrial sectors.
iDP Valves – 2-Port 350/351 Series
Inert Diaphragm-Poppet Valve
Introducing the Humphrey 350/351 series iDP valves, engineered for controlling aggressive liquids and gases in harsh environments. The diaphragm-poppet design isolates the solenoid from media penetration, while the inert body materials ensure long-lasting performance and chemical resistance.
Features:
- Elastomers Available: EPDM, VitonTMGF, or FFKM for multi-level chemical protection.
- Inert Wetted Materials: Broad chemical compatibility for a range of harsh chemicals.
-
Pressure Range:
- Standard: 0-40 PSI (2.76 bar)
- Optional: 28”Hg - 40 PSI
- Consult factory for higher pressure requirements.
-
Flow Rates @ 40 PSI:
- 220 SLPM (air)
- 5.3 SLPM (water)
- Diaphragm-Poppet Isolation: Ensures flow path is isolated from solenoid.
- Continuous-Duty Coil: Encapsulated coil suitable for wet environments.
- Temperature Tolerance: Up to 203°F (95°C) for fluid temperatures.
- Durable Design: Ensures long service life with 100% factory testing.
- Porting and Mounting Flexibility: Offers design adaptability.
Specifications Table:
Specification | IDP 350 | IDP 351 |
---|---|---|
Type of Operation | Direct Solenoid, Media Separated | Direct Solenoid, Media Separated |
Function | 2-Way, Normally Closed | 2-Way, Normally Closed |
Media | Aggressive Liquids (Gases) | Aggressive Liquids (Gases) |
Wetted Parts | Radel® and FFKM, VitonTMGF or EPDM | Radel® and FFKM, VitonTMGF or EPDM |
Pressure Range | Standard: 0-40 PSI (2.76 bar); Optional: VAC 28”Hg - 40 PSI | Standard: 0-40 PSI (2.76 bar); Optional: VAC 28”Hg - 40 PSI |
Piping Type | Inline, Direct Piping, Manifold Mount | Inline, Direct Piping, Manifold Mount |
Internal Volume (Barb Body) | Unactuated Under Poppet: 0.026in³; Actuated: 0.062in³ | Unactuated Under Poppet: 0.004in³; Actuated: 0.037in³ |
Water Flow @ 40 PSI | 5.3 SLPM | 5.3 SLPM |
Air Flow @ 40 PSI | 220 SLPM | 220 SLPM |
Fluid Temperature Range | EPDM: -20°C to 95°C; FKM, FFKM: 0-95°C | EPDM: -20°C to 95°C; FKM, FFKM: 0-95°C |
Ambient Temperature Range | EPDM: -20°C to 65°C; FKM, FFKM: 0-65°C | EPDM: -20°C to 65°C; FKM, FFKM: 0-65°C |
Cycles/Minute | 300 | 300 |
Response Time @ 40 PSI | 16 ms | 16 ms |
Port Size | 5/16” Barb; 8mm | 5/16” Barb; 8mm |
Electrical Entry | Spade Terminals or Lead Wires | Spade Terminals or Lead Wires |
Voltage | 24VDC | 24VDC |
Voltage Tolerance | ±10% | ±10% |
Power Consumption (Watts) | 8.3 | 8.3 |
Weight | 0.38 lbs | 0.39 lbs |
Media Compatibility:
- Concentrated Nitric Acid
- Sodium Hydroxide
- Ethylene Diamine
- Ethylene Glycol
- Renaline®
- Acetic/Citric Acids
- Formaldehyde
- Biological Solutions
- Sodium Hypochlorite
- Dextrose/Sugars
- Dialysate
- Hydrogen Peroxide
- Bleach/Lye
- Most other media (consult factory for compatibility).
Applications & Markets:
- Kidney Dialysis
- Analytical Chemistry
- Diagnostic Systems
- Agent Detection
- Environmental Monitoring
- Food and Beverage
- Gaseous Flow Control
- Water Purification
- Clinical Equipment Waste Systems
iDP Valves – 3-Port 370/371 Series
Inert Diaphragm-Poppet Valve
Introducing the Humphrey 370/371 series iDP valves, engineered to control aggressive liquids and gases in harsh environments. These 3-way inert solenoid valves utilize a flexing diaphragm-poppet design, isolating the solenoid from media penetration. The inert body materials ensure long-lasting performance and chemical resistance. The 370/371 series can be used as either a selector valve or diverter valve. In selector applications, the rated pressure is up to 30 PSI.
Features:
- Elastomers Available: EPDM, Viton®GF, or FFKM, providing multi-level chemical protection.
- Inert Wetted Materials: Broad chemical compatibility for harsh chemicals.
- Max Pressure: 40 PSI (2.76 bar) standard.
-
Flow Rates @ 40 PSI:
- 220 SLPM (air)
- 5.3 SLPM (water)
- Diaphragm-Poppet Isolation: Isolates the flow path from the solenoid.
- Continuous-Duty Coil: Encapsulated coil designed for wet environments.
- Temperature Resistance: Suitable for high fluid temperatures – up to 203°F (95°C).
- Durable Design: Ensures long service life with 100% factory testing.
- Flexible Design: Offers various porting and mounting options for system adaptability.
Specifications Table:
Specification | IDP 370 | IDP 371 |
---|---|---|
Type of Operation | Direct Solenoid, Media Separated | Direct Solenoid, Media Separated |
Function | 3-Way, Normally Closed | 3-Way, Normally Closed |
Media | Aggressive Liquids (Gases) | Aggressive Liquids (Gases) |
Wetted Parts | Radel® and FFKM, Viton®GF or EPDM | Radel® and FFKM, Viton®GF or EPDM |
Pressure Range | 0-40 PSI (2.76 bar); Consult factory for higher pressure or vacuum applications | 0-40 PSI (2.76 bar); Consult factory for higher pressure or vacuum applications |
Piping Type | Inline, Direct Piping, Manifold Mount | Inline, Direct Piping, Manifold Mount |
Internal Volume (Barb Body) | Unactuated Under Poppet: 0.026in³; Actuated: 0.062in³ | Unactuated Under Poppet: 0.004in³; Actuated: 0.037in³ |
Water Flow @ 40 PSI | 5.3 SLPM | 5.3 SLPM |
Air Flow @ 40 PSI | 220 SLPM | 220 SLPM |
Fluid Temperature Range | EPDM: -20°C to 95°C; FKM, FFKM: 0-95°C | EPDM: -20°C to 95°C; FKM, FFKM: 0-95°C |
Ambient Temperature Range | EPDM: -20°C to 65°C; FKM: -10°C to 65°C; FFKM: 10-65°C | EPDM: -20°C to 65°C; FKM: -10°C to 65°C; FFKM: 10-65°C |
Cycles/Minute | 300 | 300 |
Response Time @ 40 PSI | 20 ms | 20 ms |
Port Size | 5/16” Barb; 8mm | 5/16” Barb; 8mm |
Electrical Entry | Spade Terminals or Lead Wires | Spade Terminals or Lead Wires |
Voltage | 24VDC | 24VDC |
Voltage Tolerance | ±10% | ±10% |
Power Consumption (Watts) | 8.3 | 8.3 |
Weight | 0.40 lbs | 0.42 lbs |
Media Compatibility:
- Citric Acid
- Formaldehyde
- Biological Solutions
- Sodium Hypochlorite
- Dextrose/Sugars
- Dialysate
- Hydrogen Peroxide
- Acetic Acid
- Bleach/Lye
- Most aggressive medias (consult factory for compatibility).
Applications & Markets:
- Kidney Dialysis
- Analytical Chemistry
- Diagnostic Systems
- Agent Detection
- Environmental Monitoring
- Food and Beverage
- Gaseous Flow Control
- Water Purification
- Clinical Equipment Waste Systems
MiDP Valves – 2-Port S390/S391 Stepper Operated
Inert Diaphragm Poppet Proportional Valves
Introducing the Humphrey MiDP Series Proportional Valves, designed to provide precise control of flow for a wide range of aggressive liquids and gases. These valves utilize the Humphrey 350 Series diaphragm-isolated design, a proven and reliable technology in the medical industry (20+ years of service), including applications such as kidney dialysis and endoscope reprocessing. The flow path is safely isolated from the media, ensuring high-performance control through a stepper motor operator. This motor delivers exceptional repeatability, precise positioning, and low hysteresis.
Features:
- Proven Reliability: Diaphragm-separated body construction from the Humphrey 350 Series iDP Valves.
- Inert Wetted Flow Path: Made of a Radel® body with diaphragm materials available in FFKM, EPDM, or VitonTMGF, ensuring broad chemical and temperature compatibility.
- Precise Flow Control: Extremely repeatable flow control with a typical deviation of less than 2% of full scale.
- Low Hysteresis: Hysteresis measured at less than 2%, making open-loop control applications feasible.
- Cavitation Resistant: Not susceptible to cavitation or water hammer (in liquids).
- Efficient Positioning: Low or zero holding current when positioned.
- Long Life: Designed for durability with a cycle life exceeding 1 million cycles.
- Custom Configurations: Available on request for tailored performance (consult factory).
- Flexible Mounting Options: Inline/direct piping and manifold/subbase mount bodies.
Specifications Table:
Specification | MiDP S390, MiDP S391 |
---|---|
Type of Operation | Stepper Motor, Media Isolated |
Media | Aggressive Liquid or Gas |
Pressure Range | 0 - 60 PSI (0 - 4.1 bar) |
Typical Hysteresis | < 2% |
Typical Flow Range (0.150” Orifice) | 0-8.5 SLPM (Water) / 0-325 SLPM (Air) @ 60 PSI |
Typical Flow Adjustment per Step @ 40 PSI (0.150” Orifice) | Air: 5.3 SLPM |
Cv (0.150” Orifice) | 0.31 |
Ambient Temperature | 0 - 50°C |
Fluid Temperature | 0 - 95°C |
Cycle Time (Open to Close or Close to Open) | 2 seconds |
Cycle Life | > 1 million cycles |
Step Response Time | < 40 milliseconds |
Repeatability | < 2% of full scale |
Stroke (in) | 0 - 0.024 |
Position Resolution (in) | 0.0004 / Step |
Wetted Materials | Radel®, EPDM, VitonTMGF, FFKM |
Power Consumption (Watts) | 2.6 MAX |
Current / Phase | 600 mA standard; Consult factory for other options |
Driver (Customer Supplied) | Chopper or Linear Driver Required |
Media Compatibility:
- Citric Acid
- Formaldehyde
- Biological Solutions
- Sodium Hypochlorite
- Dextrose/Sugars
- Dialysate
- Hydrogen Peroxide
- Acetic Acid
- Bleach/Lye
- Most aggressive medias (consult factory for compatibility).
Applications & Markets:
- Kidney Dialysis
- Diagnostic Systems
- Environmental Monitoring
- Food and Beverage
- Gaseous Flow Control
- Water Purification
- Clinical Equipment Waste Systems
- Ratio Control of Mixing Multiple Liquids
- Dosing Additives for Process Control