Directional Control Air Valves & Accessories
STAINLESS STEEL 316 SERIES
Ordering Information for Stainless Steel 316 Series:
- Series: 316 identifies stainless steel 316 series.
- Operator "B": This is the secondary operator. It returns the spool to the start position.
-
Body Style:
- 1/8” body available in 4-Way only, but can be plugged to make 3-Way or 2-Way.
- Operator "A": This is the primary operator that moves the spool away from the start position.
- Specify Voltages: Include voltage specifications or any special conditions.
OPERATOR TYPES:
- Blank end cap
- Spring end cap
- Air pilot
- Lever detented parallel push-pull
- Conduit connection locking manual override
- Explosion-proof conduit connection, locking manual override, stainless steel
(Denotes standard voltages)
ENGINEERING & TECHNICAL DATA
-
Material:
316 series – Metal components are 316 stainless steel, excluding standard solenoid operator. -
Body Style:
1/4 NPTF ported – 3-Way and 4-Way bodies. -
Configurations:
Solenoid, air, and manual actuators. In-line configuration. -
Lubrication:
All valves are pre-lubricated and will operate dry (with no additional lubrication). However, a lubricated system will greatly extend the service life of any valve. -
“Thin-Lip” Seal & Spool:
- PTFE-loaded Viton seals provide millions of trouble-free cycles.
- Minimal breakout friction.
- Unique wiping action eliminates contaminant buildup in the bore.
- Reduces spool hang-up due to compressor or oil varnishing.
- Operates effectively in lubricated or non-lubricated systems.
SOLENOID HOUSING CLASSIFICATIONS
Conduit and Grommet Housings with Molded Coils Meet:
- NEMA 1 General Purpose: Indoors
- NEMA 2 Dripproof: Indoors
- NEMA 3 Driptight: Indoors
- NEMA 4* Watertight & Dusttight: Indoors & Outdoors
- NEMA 6* Submersible, Watertight, Dusttight & Sleet-Ice Resistant: Indoors & Outdoors
*Specify “Potted” coil option to meet NEMA 4 & 6.
Explosion-Proof Housings Meet:
- NEMA 7C, 7D & CSA Class I: Groups C & D (Explosion Proof)
- NEMA 8C, 8D & CSA Class I: Groups C & D (Explosion Proof)
- NEMA 9E, 9F, 9G & CSA Class II: Groups E, F & G (Explosion Proof)
VALVE OPERATING SPECIFICATIONS
-
Media: Air & Gas
-
Pressure Range:
- Main Supply: 40-150 psig (standard)
- Vacuum to 40 psig is available
- Solenoid Pilot Air: Minimum 40 psig to 150 psig, and not less than the main air supply. For lower pilot pressure, consult factory.
-
Temperature Range:
0°C to 85°C (32°F to 180°F)
For other temperatures, consult the factory. -
Flow Data:
Port Cv SCFM at 80 psi
1/4 NPT: 2.2 104
REPLACEMENT PARTS / SPOOL REPLACEMENT
-
Air & Solenoid S.S.
1/4 NPTF Single & Double Pilot: 90A20295
SOLENOID DATA
Standard Voltages:
Voltage | Current (Amps) |
---|---|
120/60 AC | Inrush: .11 Amps |
24 VDC | Inrush: .29 Amps |
Other AC and DC voltages available on special order.
Note: 120/60Hz can be connected to 110/50Hz.
Molded epoxy coils are standard.
Explosion-proof solenoids available.
COIL REPLACEMENT
-
Description:
Coil with conduit housing for 38 operators: 26A01017
Coil for explosion-proof housing for 41 operators: 26A01043
When ordering coils, provide the part number and voltage.
Standard voltages are: 120/60, 24 VDC. For other voltages, consult factory.