PRODUCTS >> Air Preparation >> Regulators >> General Purpose >> Control Air Type 400 Regulator

Control Air Type 400 Regulator

 
Materials:Body: diecast aluminum alloy. Diaphragm: nitrile elastomer and nylon fabric. Trim: brass, zinc plated steel, acetal.
Flow Capacity
20 SCFM (570 Nl/min) at 100 psig (7 BAR) supply 20 psig (1.4 BAR) outlet.
Exhaust Capacity
0.1 SCFM (28 Nl/min) downstream pressure 5 psig (0.3 BAR) above set point.
Sensitivity
1" (2.5 cm) of water
Effect of Supply Pressure Variation
less than 2 psig(0.014 BAR) for 25 psi (1.7 BAR) change
Maximum Supply Pressure
250 psig (17 BAR)
Air Consumption
less than 6 SCFH (170 Nl/min)
Output Range
0-30 psig (0-2 BAR), 0-60 psig (0-4 BAR), 0-120 psig (0-8 BAR)
Port Size
1/4" NPT
Mounting
Pipe or panel
Ordering Information
Part
Number
Port Size
(NPT)
Output Range
psi
bar 
400-BD
1/4"
0-10
0-0.7
400-BA
1/4"
0-30
0-2
400-BB
1/4"
0-60
0-4
400-BC
1/4"
0-120
0-8
 
OPTIONS Add proper letter onto end of model number:
K - Knob: to replace square head adjust screw.
E - Tapped Exhaust: allows captured exhaust air. 1/4" NPT port.
N - Non-Relieving: for constant flow or downstream pressure relief applications.
T - Tamperproof Cover: prevents casual adjustment of output pressure.
S - Stainless Steel Adjust Screw: hexhead stainless steel adjust screw for maximum corrosion resistance.
V - Viton® Elastomers: used where elements in the supply air are particularly destructive to standard Buna-N pintle and diaphragm material.
ACCESSORIES
B - Mounting Bracket: zinc-plated steel bracket for side mounting P/N: 446-707-028
Pressure Gauge - 1/4" NPT back-mount, 2" face
0-30 psi (0-2 BAR) P/N: 446-725-004
0-60 psi (0-4 BAR) P/N: 446-725-001
0-160 psi (0-8 BAR) P/N: 446-725-002
 
 
 
 